Histologic evaluation of human bone integration on machined and sandblasted acid-etched titanium surfaces in type IV bone.

Sauro Grassi1, Adriano Piattelli, Daniel S Ferrari, Luciene C Figueiredo, Magda Feres, Giovanna Iezzi, Jamil Awad Shibli.   

Abstract

The aim of this preliminary study was to evaluate the influence of a sandblasted acid-etched surface on bone-implant contact percentage (BIC%) as well as the bone density in the threads area (BD%) in type 4 bone after 2 months of unloaded healing. Five subjects (mean age = 42.6 years) received 2 microimplants each during conventional implant surgery in the posterior maxilla. The microimplants with commercially pure titanium surface (machined) and sandblasted acid-etched surface served as the control and test surfaces, respectively. After a healing period of 2 months, the microimplants and the surrounding tissue were removed and prepared for ground sectioning and histomorphometric analysis. One microimplant with a machined surface was found to be clinically unstable at the time of retrieval. Histometric evaluation indicated mean BIC% was 20.66+/-14.54% and 40.08+/- 9.89% for machined and sandblasted acid-etched surfaces, respectively (P=.03). The BD% was 26.33 +/-19.92% for machined surface and 54.84+/-22.77% for sandblasted acid-etched surface (P=.015). Within the limits of this study, the data suggest that the sandblasted acid-etched implant surface presented a higher percentage of bone-implant contact compared with machined surfaces, under unloaded conditions in posterior maxilla after a healing period of 2 months.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17410906     DOI: 10.1563/0-791.1

Source DB:  PubMed          Journal:  J Oral Implantol        ISSN: 0160-6972            Impact factor:   1.779


  4 in total

Review 1.  Recent Nanotechnology Approaches for Prevention and Treatment of Biofilm-Associated Infections on Medical Devices.

Authors:  Mohankandhasamy Ramasamy; Jintae Lee
Journal:  Biomed Res Int       Date:  2016-10-31       Impact factor: 3.411

2.  The influence of length of implant on primary stability: An in vitro study using resonance frequency analysis.

Authors:  Anwar B Bataineh; Ala M Al-Dakes
Journal:  J Clin Exp Dent       Date:  2017-01-01

3.  A Newly Created Meso-, Micro-, and Nano-Scale Rough Titanium Surface Promotes Bone-Implant Integration.

Authors:  Masakazu Hasegawa; Juri Saruta; Makoto Hirota; Takashi Taniyama; Yoshihiko Sugita; Katsutoshi Kubo; Manabu Ishijima; Takayuki Ikeda; Hatsuhiko Maeda; Takahiro Ogawa
Journal:  Int J Mol Sci       Date:  2020-01-25       Impact factor: 5.923

4.  Histological characteristics of advanced peri-implantitis bone defects in humans.

Authors:  Maria Elisa Galárraga-Vinueza; Stefan Tangl; Marco Bianchini; Ricardo Magini; Karina Obreja; Reinhard Gruber; Frank Schwarz
Journal:  Int J Implant Dent       Date:  2020-03-25
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.