Literature DB >> 17410500

Mechanical aortic and mitral valve replacement in infants and children.

J S Sachweh1, A R Tiete, E G Mühler, J Groetzner, H Gulbins, B J Messmer, S H Daebritz.   

Abstract

BACKGROUND: The aim of this study was to evaluate early and late outcomes after mechanical systemic heart valve replacement in pediatric patients.
METHODS: Between October 1981 and December 2003, 32 children (mean age 7.2 +/- 5.4 years; 4 months - 15.9 years) underwent mechanical mitral (MVR, n = 17), aortic (AVR, n = 13) or double valve replacement (DVR, n = 2) with St. Jude Medical valves. Twenty-two patients (69 %) had undergone previous cardiac surgery. Anticoagulation self-management was used since 1995.
RESULTS: The operative mortality was 3.1 %. Perioperative complications were complete heart block (n = 5), ventricular fibrillation (n = 1) and myocardial infarction (n = 1) and were exclusively related to patients with MVR. Mean calculated valve size ratio (geometric prosthesis orifice area/normal valve size area) was 1.72 (1.07 - 2.85) for AVR and 1.4 (0.88 - 3.12) for MVR. Mean follow-up was 9.1 +/- 6.6 years (range 0.4 - 23.2 years, cumulative 283 patient-years). There were two late deaths in patients with MVR. Actuarial survival after 10 years was 93.8 %. Late complications were endocarditis (n = 2), minor hemorrhagic event (n = 1), and stroke (n = 1). Anticoagulation self-management is well accepted by all patients/parents. Overall 10-year freedom from any anticoagulation-related adverse event with phenprocoumon was 89.1 % (1.2 %/patient year). Nine patients required reoperations: redo-MVR (outgrowth of prostheses (n = 3), pannus overgrowth (n = 2), closure of paravalvular leak after AVR (n = 2), partial aortic valve thrombosis (n = 1) and redo-DVR (n = 1 for endocarditis). Freedom from reoperation after 10 years was 80.9 %.
CONCLUSIONS: Mechanical valve prostheses are a valuable option for left-sided heart valve replacement in pediatric patients. Perioperative morbidity was exclusively related to patients with MVR. Oversizing was often possible to avoid early reoperation for outgrowth. The operative mortality and long-term morbidity are acceptable. Anticoagulation self-management is safe and well accepted.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17410500     DOI: 10.1055/s-2006-924627

Source DB:  PubMed          Journal:  Thorac Cardiovasc Surg        ISSN: 0171-6425            Impact factor:   1.827


  4 in total

1.  Antithrombotic therapy in neonates and children: Antithrombotic Therapy and Prevention of Thrombosis, 9th ed: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines.

Authors:  Paul Monagle; Anthony K C Chan; Neil A Goldenberg; Rebecca N Ichord; Janna M Journeycake; Ulrike Nowak-Göttl; Sara K Vesely
Journal:  Chest       Date:  2012-02       Impact factor: 9.410

2.  Long-term outcomes of mitral valve replacement in patients weighing less than 10 kg.

Authors:  Haoyong Yuan; Zhongshi Wu; Ting Lu; Yilun Tang; Jinlan Chen; Yifeng Yang; Can Huang
Journal:  J Cardiothorac Surg       Date:  2021-03-31       Impact factor: 1.637

3.  Surgical techniques for aortic valve xenotransplantation.

Authors:  Jennie H Kwon; Morgan Hill; Brielle Gerry; Steven W Kubalak; Muhammad Mohiuddin; Minoo N Kavarana; T Konrad Rajab
Journal:  J Cardiothorac Surg       Date:  2021-12-28       Impact factor: 1.637

4.  Long-Term Outcome Up To 40 Years after Single Patch Repair of Complete Atrioventricular Septal Defect in Infancy or Childhood.

Authors:  Stefanie Reynen; Hedwig H Hövels-Gürich; Jaime F Vazquez-Jimenez; Bruno J Messmer; Joerg S Sachweh
Journal:  Thorac Cardiovasc Surg       Date:  2021-12-25       Impact factor: 1.827

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.