Literature DB >> 17410375

Hand vibration: non-contact measurement of local transmissibility.

Lorenzo Scalise1, Francesco Rossetti, Nicola Paone.   

Abstract

OBJECTIVES: Grip and push forces required for the use of vibrating tools are considered important influencing inputs for the assessment of hand-vibration transmissibility (TR). At present TR measurements are usually referred to the palm of the hand The aims of the present paper are: to present an original measurement procedure for non-contact assessment of the transmissibility of fingers; to report TR data measured on six points of the hand of nine subjects; to correlate TR with: grip, push, hand volume and BMI.
METHODS: Tests have been carried out using a cylindrical handle mounted on an shaker. A laser Doppler vibrometer is used to measure the vibration velocity. Push force is measured using a force platform, whereas grip force is measured using a capacitive pressure sensor matrix wrapped around the handle. Tests have been conducted on nine healthy subjects. Proximal and distal regions of the second, fourth and fifth fingers have been investigated. Tests were carried out using a push force of: 25, 50 and 75 N. The excitation signal was a broadband random vibration in the band 16-400 Hz with un-weighted rms acceleration level of 6 m/s(2).
RESULTS: Results show how in general TR values measured on distal points are higher respect to the proximal points. A resonance peak is present for all the measured points in the band 55-80 Hz. ANOVA analysis showed that TR is not significantly dependent on: BMI, hand volume and push force alone. While TR is significantly dependent on: grip force alone, measurement positions and grip and push force together.
CONCLUSIONS: The proposed procedure shows the advantage to allow local vibration measurement directly on the fingers without the necessity to apply any contact sensor. Results demonstrate how the transmissibility is significantly different on the point where the acceleration is measured.

Mesh:

Year:  2007        PMID: 17410375     DOI: 10.1007/s00420-007-0190-3

Source DB:  PubMed          Journal:  Int Arch Occup Environ Health        ISSN: 0340-0131            Impact factor:   3.015


  7 in total

1.  A method for reducing adaptor misalignment when testing gloves using ISO 10819.

Authors:  W P Smutz; R G Dong; B Han; A W Schopper; D E Welcome; M L Kashon
Journal:  Ann Occup Hyg       Date:  2002-04

2.  A new method for the experimental assessment of finger haemodynamic effects induced by a hydraulic breaker in operative conditions.

Authors:  Matteo Valentino; Venerando Rapisarda; Lorenzo Scalise; Nicola Paone; Lory Santarelli; Concettina Fenga; Gian Luca Rossi
Journal:  J Occup Health       Date:  2004-07       Impact factor: 2.708

3.  Hand-arm vibration syndrome.

Authors:  Erica Weir; Lina Lander
Journal:  CMAJ       Date:  2005-04-12       Impact factor: 8.262

Review 4.  Exposure-response relationship in the hand-arm vibration syndrome: an overview of current epidemiology research.

Authors:  M Bovenzi
Journal:  Int Arch Occup Environ Health       Date:  1998-11       Impact factor: 3.015

5.  Assessing the performance of anti-vibration gloves--a possible alternative to ISO 10819, 1996.

Authors:  S Hewitt
Journal:  Ann Occup Hyg       Date:  1998-05

6.  Transmission of vibration energy to different parts of the human hand-arm system.

Authors:  A Sörensson; L Burström
Journal:  Int Arch Occup Environ Health       Date:  1997       Impact factor: 3.015

7.  Human hand-transmitted vibration measurements on pedestrian controlled tractor operators by a laser scanning vibrometer.

Authors:  R Deboli; G Miccoli; G L Rossi
Journal:  Ergonomics       Date:  1999-06       Impact factor: 2.778

  7 in total
  6 in total

1.  A proposed theory on biodynamic frequency weighting for hand-transmitted vibration exposure.

Authors:  Ren G Dong; Daniel E Welcome; Thomas W McDowell; Xueyan S Xu; Kristine Krajnak; John Z Wu
Journal:  Ind Health       Date:  2012       Impact factor: 2.179

2.  An examination of the handheld adapter approach for measuring hand-transmitted vibration exposure.

Authors:  Xueyan S Xu; Ren G Dong; Daniel E Welcome; Christopher Warren; Thomas W McDowell
Journal:  Measurement ( Mahwah N J)       Date:  2014-01

3.  Laser doppler myography (LDMi): A novel non-contact measurement method for the muscle activity.

Authors:  L Scalise; S Casaccia; P Marchionni; I Ercoli; Ep Tomasini
Journal:  Laser Ther       Date:  2013-12-30

4.  An examination of the vibration transmissibility of the hand-arm system in three orthogonal directions.

Authors:  Daniel E Welcome; Ren G Dong; Xueyan S Xu; Christopher Warren; Thomas W McDowell; John Z Wu
Journal:  Int J Ind Ergon       Date:  2015-02       Impact factor: 2.656

5.  The effects of vibration-reducing gloves on finger vibration.

Authors:  Daniel E Welcome; Ren G Dong; Xueyan S Xu; Christopher Warren; Thomas W McDowell
Journal:  Int J Ind Ergon       Date:  2014-01       Impact factor: 2.656

6.  An examination of an adapter method for measuring the vibration transmitted to the human arms.

Authors:  Xueyan S Xu; Ren G Dong; Daniel E Welcome; Christopher Warren; Thomas W McDowell
Journal:  Measurement (Lond)       Date:  2015-09       Impact factor: 3.927

  6 in total