Literature DB >> 17405365

Mathematical model for the hemodynamic response to venous occlusion measured with near-infrared spectroscopy in the human forearm.

Toi Van Vo1, Peter E Hammer, Matthew L Hoimes, Shalini Nadgir, Sergio Fantini.   

Abstract

We propose a mathematical model to describe the hemodynamic changes induced by a venous occlusion in a human limb. These hemodynamic changes, which include an increase in blood volume, a reduction in blood flow, and modifications to the oxygen saturation of hemoglobin, can all be measured noninvasively with near-infrared spectroscopy (NIRS). To test the model, we have performed NIRS measurements on the human forearm, specifically on the brachioradialis muscle, during venous occlusion induced by a pneumatic cuff inflated around the upper arm to pressures within the range 10-60 mmHg. We have found a good agreement between parameters measured by NIRS (total hemoglobin concentration and hemoglobin saturation) and the corresponding model parameters (capacitor voltage and arterial/capillary branch current). In particular, model and experiment indicate that the time constant for blood accumulation during venous occlusion (approximately 73-79 s) is much slower than the time constant for blood drainage following cuff release (approximately 5 s). These results indicate that this mathematical model can be a valuable analytical tool to characterize, optimize, and further develop diagnostic measurement schemes that use venous occlusion approaches.

Entities:  

Mesh:

Year:  2007        PMID: 17405365     DOI: 10.1109/TBME.2006.890123

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  4 in total

Review 1.  Implicit and explicit prior information in near-infrared spectral imaging: accuracy, quantification and diagnostic value.

Authors:  Brian W Pogue; Scott C Davis; Frederic Leblond; Michael A Mastanduno; Hamid Dehghani; Keith D Paulsen
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2011-11-28       Impact factor: 4.226

2.  Effective CPR Procedure With Real Time Evaluation and Feedback Using Smartphones.

Authors:  Neeraj K Gupta; Vishnu Dantu; Ram Dantu
Journal:  IEEE J Transl Eng Health Med       Date:  2014-05-30       Impact factor: 3.316

3.  Spectral and spatial dependence of
diffuse optical signals in response to
peripheral nerve stimulation.

Authors:  Debbie K Chen; M Kelley Erb; Yunjie Tong; Yang Yu; Angelo Sassaroli; Peter R Bergethon; Sergio Fantini
Journal:  Biomed Opt Express       Date:  2010-09-16       Impact factor: 3.732

4.  Validation of the mean systemic filling pressure assessment with preserved arterial blood flow by comparing two methods of calculation.

Authors:  Roberto Alberto De Blasi; Stefano Finazzi
Journal:  Sci Rep       Date:  2021-08-04       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.