The application of maximum likelihood factor analysis (MLFA) with uniqueness constraints on dynamic cardiac microPET data.

Yi Su1, Michael J Welch, Kooresh I Shoghi.   

Abstract

A maximum likelihood framework for factor analysis (MLFA) of dynamic images was developed. This framework allows for the introduction of weighting factors to account for the differences in signal-to-noise ratio and frame durations in the dynamic images. An efficient iterative algorithm was developed to solve the maximum likelihood problem with non-negativity constraint embedded inside the iteration loop. To address the non-uniqueness issue, blood samples as well as two different constraint strategies were employed to resolve ambiguities in the time activity curves (TAC) and factor images. Four weighting mechanisms were implemented and the algorithms were thoroughly tested using simulation studies at different signal-to-noise ratios and with different kinetic parameter realizations. In addition, rodent dynamic cardiac FDG microPET datasets were used for further validation of our algorithms. It was demonstrated that with appropriate constraints, our MLFA approach is capable of generating accurate blood input function and pure tissue TACs. The MLFA algorithm with an accompanying graphical user interface (GUI) is available at http://www.chempet.wustl.edu/faculty/shoghik.

Mesh:

Year:  2007        PMID: 17404471     DOI: 10.1088/0031-9155/52/8/018

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  14 in total

Review 1.  Dynamic single photon emission computed tomography--basic principles and cardiac applications.

Authors:  Grant T Gullberg; Bryan W Reutter; Arkadiusz Sitek; Jonathan S Maltz; Thomas F Budinger
Journal:  Phys Med Biol       Date:  2010-09-22       Impact factor: 3.609

Review 2.  Recent advances in metabolic imaging.

Authors:  Robert J Gropler
Journal:  J Nucl Cardiol       Date:  2013-12       Impact factor: 5.952

Review 3.  Dynamic whole-body PET imaging: principles, potentials and applications.

Authors:  Arman Rahmim; Martin A Lodge; Nicolas A Karakatsanis; Vladimir Y Panin; Yun Zhou; Alan McMillan; Steve Cho; Habib Zaidi; Michael E Casey; Richard L Wahl
Journal:  Eur J Nucl Med Mol Imaging       Date:  2018-09-29       Impact factor: 9.236

4.  Noninvasive estimation of the arterial input function in positron emission tomography imaging of cerebral blood flow.

Authors:  Yi Su; Ana M Arbelaez; Tammie L S Benzinger; Abraham Z Snyder; Andrei G Vlassenko; Mark A Mintun; Marcus E Raichle
Journal:  J Cereb Blood Flow Metab       Date:  2012-10-17       Impact factor: 6.200

5.  [Kinetic cluster and α-divergence-based dynamic myocardial factorial analysis of positron-emission computed tomography images].

Authors:  Pei-Pei Wang; Li-Jun Lu; Shuang-Liang Cao; Hua-Yong Li; Wu-Fan Chen
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2017-12-20

6.  Simplified [18F]FDG image-derived input function using the left ventricle, liver, and one venous blood sample.

Authors:  Mohammed Noor Tantawy; Todd E Peterson
Journal:  Mol Imaging       Date:  2010-04       Impact factor: 4.488

7.  Single-input-dual-output modeling of image-based input function estimation.

Authors:  Yi Su; Kooresh I Shoghi
Journal:  Mol Imaging Biol       Date:  2009-12-01       Impact factor: 3.488

8.  Kinetic quantitation of cerebral PET-FDG studies without concurrent blood sampling: statistical recovery of the arterial input function.

Authors:  F O'Sullivan; J Kirrane; M Muzi; J N O'Sullivan; A M Spence; D A Mankoff; K A Krohn
Journal:  IEEE Trans Med Imaging       Date:  2009-08-25       Impact factor: 10.048

9.  PET imaging of in vivo caspase-3/7 activity following myocardial ischemia-reperfusion injury with the radiolabeled isatin sulfonamide analogue [(18)F]WC-4-116.

Authors:  Arun K Thukkani; Kooresh I Shoghi; Dong Zhou; Jinbin Xu; Wenhua Chu; Eric Novak; Delphine L Chen; Robert J Gropler; Robert H Mach
Journal:  Am J Nucl Med Mol Imaging       Date:  2016-04-24

10.  Wavelet denoising in voxel-based parametric estimation of small animal PET images: a systematic evaluation of spatial constraints and noise reduction algorithms.

Authors:  Yi Su; Kooresh I Shoghi
Journal:  Phys Med Biol       Date:  2008-10-03       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.