Literature DB >> 17403884

The 3DX multi image micro-CT device in clinical dental practice.

A K Suomalainen1, A Salo, S Robinson, J S Peltola.   

Abstract

OBJECTIVES: To evaluate the usefulness of 3DX multi-image micro-CT device in clinical dental practice.
METHODS: Images of 198 examinations performed with a 3DX device during a 6 month period in a private dental practice were evaluated retrospectively for the benefit of additional information compared with panoramic or intraoral radiographs.
RESULTS: The main indication for the use of 3DX micro-CT was planning of dental implant placement in 49% of the examinations. Diagnosis or exclusion of dental infection or peri-implantitis represented 28% of the examinations and tooth, root or foreign body localization represented 13%. Temporomandibular joint (TMJ) imaging and cyst or tumour diagnosis represented 7.5% and 2.5% of the examinations, respectively. In implant planning and tooth, root or foreign body localization examinations, the required information was obtained in every case except three implant planning examinations, in which the exact measurements were hampered by artefacts caused by root fillings and retrograde fillings or metal posts. When compared with conventional radiography, additional radiographic information was obtained in 51% of the micro-CT examinations performed to confirm or exclude dental infection or peri-implantitis. Micro-CT also showed the bone structure of TMJs precisely.
CONCLUSIONS: The 3DX micro-CT device visualizes bony anatomical structures precisely, which makes it a reliable tool for, for example, planning of implant treatment. The device is highly suitable for diagnosing dental infections. Dental restorations may cause disturbing artefacts and in 4.5% of the examinations the small imaging area resulted in re-examination.

Entities:  

Mesh:

Year:  2007        PMID: 17403884     DOI: 10.1259/dmfr/30358216

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  6 in total

1.  Deriving Hounsfield units using grey levels in cone beam computed tomography.

Authors:  P Mah; T E Reeves; W D McDavid
Journal:  Dentomaxillofac Radiol       Date:  2010-09       Impact factor: 2.419

2.  Detection of dental root fractures by using cone-beam computed tomography.

Authors:  P Wang; X B Yan; D G Lui; W L Zhang; Y Zhang; X C Ma
Journal:  Dentomaxillofac Radiol       Date:  2011-07       Impact factor: 2.419

3.  Self-calibration of a cone-beam micro-CT system.

Authors:  V Patel; R N Chityala; K R Hoffmann; C N Ionita; D R Bednarek; S Rudin
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071

4.  Cone beam computed tomography for assessment of root length and marginal bone level during orthodontic treatment.

Authors:  Henrik Lund; Kerstin Gröndahl; Hans-Göran Gröndahl
Journal:  Angle Orthod       Date:  2010-05       Impact factor: 2.079

5.  Apical root resorption during orthodontic treatment. A prospective study using cone beam CT.

Authors:  Henrik Lund; Kerstin Gröndahl; Ken Hansen; Hans-Göran Gröndahl
Journal:  Angle Orthod       Date:  2011-09-16       Impact factor: 2.079

6.  Mechanical or cold lateral compaction: The incidence of dentinal defects.

Authors:  Seyed Mohsen Hasheminia; Ali Reza Farhad; Masoud Saatchi; Hamidreza Sadegh Nejad; Maryam Sanei
Journal:  Dent Res J (Isfahan)       Date:  2015 Nov-Dec
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.