Literature DB >> 17397744

Validity of the keratometric index: large population-based study.

Han-Bor Fam1, Kooi-Ling Lim.   

Abstract

PURPOSE: To determine the accuracy of the keratometric index of 1.3315 based on the Gullstrand model eye in predicting the power of the posterior cornea, Gullstrand's model was compared to a calculated keratometric index derived from actual measurements of the cornea.
SETTING: Eye Institute, Tan Tock Seng Hospital, Singapore.
METHODS: One eye of 2429 subjects with a mean spherical equivalent of -5.32 diopters (D) +/- 2.88 (SD) was measured with the Orbscan II (Bausch & Lomb). The following variables were analyzed: anterior radius of curvature (r(anterior)), posterior radius of curvature (r(posterior)), radius of keratometry (r(simK)), and central pachymetry.
RESULTS: The r(anterior), r(posterior), and r(simK) were normally distributed, with a mean of 7.87 +/- 0.25 mm (95% confidence interval [CI], 7.38-8.36), 6.46 +/- 0.26 mm (95% CI, 5.95-6.97), and 7.71 +/- 0.27 mm (95% CI, 7.18-8.24), respectively. The mean ratio between the anterior corneal curvature and posterior corneal curvature was 1.22 +/- 0.03 (95% CI, 1.16-1.28). Based on the measurements of each eye, the mean calculated keratometric index, N(calc), was 1.3273 +/- 0.0013 (95% CI, 1.3248-1.3298). Using N(calc), the posterior corneal power was predicted to within +/-0.50 D of the actual posterior power in 98.3% of eyes. The mean absolute error between the actual and calculated posterior power was 0.157 +/- 0.123 D using N(calc) and 0.326 +/- 0.133 D using the Gullstrand model.
CONCLUSION: Modifying the keratometric index increased the accuracy of predicting the posterior corneal power.

Entities:  

Mesh:

Year:  2007        PMID: 17397744     DOI: 10.1016/j.jcrs.2006.11.023

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  14 in total

1.  Assessment of total corneal power after myopic corneal refractive surgery in Chinese eyes.

Authors:  Yanjun Hua; Chao Pan; Qinmei Wang
Journal:  Int Ophthalmol       Date:  2019-03-01       Impact factor: 2.031

2.  Anterior and posterior corneal curvature: normal values in healthy Iranian population obtained with the Orbscan II.

Authors:  Hamid Gharaee; Mojtaba Abrishami; Mostafa Abrishami; Seyyed Mohammad Mirhosseini; Mohammad Reza Mehrabi Bahar; Pardis Eghbali
Journal:  Int Ophthalmol       Date:  2014-09-25       Impact factor: 2.031

3.  Keratometric index obtained by Fourier-domain optical coherence tomography.

Authors:  Yanjun Hua; Aleksander Stojanovic; Tor Paaske Utheim; Xiangjun Chen; Sten Ræder; Jinhai Huang; Qinmei Wang
Journal:  PLoS One       Date:  2015-04-17       Impact factor: 3.240

4.  The prevalence of astigmatism and its determinants in a rural population of Iran: the "Nooravaran Salamat" mobile eye clinic experience.

Authors:  Hassan Hashemi; Farhad Rezvan; Abbas Ali Yekta; Maryam Hashemi; Reza Norouzirad; Mehdi Khabazkhoob
Journal:  Middle East Afr J Ophthalmol       Date:  2014 Apr-Jun

5.  Precision (Repeatability and Reproducibility) and Agreement of Corneal Power Measurements Obtained by Topcon KR-1W and iTrace.

Authors:  Yanjun Hua; Zequan Xu; Wei Qiu; Qiang Wu
Journal:  PLoS One       Date:  2016-01-11       Impact factor: 3.240

6.  Torsional and flattening effect on corneal astigmatism after cataract surgery: a retrospective analysis.

Authors:  Yuli Park; Hyun Seung Kim
Journal:  BMC Ophthalmol       Date:  2017-02-08       Impact factor: 2.209

7.  The distribution of orbscan indices in young population.

Authors:  Hassan Hashemi; Mehdi Khabazkhoob; Negareh Yazdani; Hadi Ostadimoghaddam; Payam Nabovati; Raheleh Moravej; AbbasAli Yekta
Journal:  J Curr Ophthalmol       Date:  2016-08-31

8.  Agreement between total corneal astigmatism calculated by vector summation and total corneal astigmatism measured by ray tracing using Galilei double Scheimpflug analyzer.

Authors:  Sepehr Feizi; Siamak Delfazayebaher; Vahid Ownagh; Fatemeh Sadeghpour
Journal:  J Optom       Date:  2017-08-04

9.  A novel color-LED corneal topographer to assess astigmatism in pseudophakic eyes.

Authors:  Tiago B Ferreira; Filomena J Ribeiro
Journal:  Clin Ophthalmol       Date:  2016-08-13

10.  Comparison of Anterior, Posterior, and Total Corneal Astigmatism Measured Using a Single Scheimpflug Camera in Healthy and Keratoconus Eyes.

Authors:  Young Choi; Youngsub Eom; Jong Suk Song; Hyo Myung Kim
Journal:  Korean J Ophthalmol       Date:  2018-05-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.