Literature DB >> 17397293

Changes in the myocardial performance index during dobutamine administration in anesthetized cats.

Yasutomo Hori1, Masami Uechi, Atsuko Indou, Shigeki Yamano, Takashi Ebisawa, Kenji Teshima, Kazushi Asano.   

Abstract

OBJECTIVE: To investigate the relationship between myocardial performance index (MPI; also known as the Tei index) and cardiac function in anesthetized cats administered dobutamine. ANIMALS: 6 adult cats. PROCEDURES: Cats were anesthetized by administration of propofol (6 mg/kg, IV), and anesthesia was maintained by administration of isoflurane. Heart rate and systolic arterial pressure (SAP) were monitored. Stroke volume, cardiac output, and aortic blood flow (ABF) were measured by use of transesophageal ultrasonography. Left ventricular fractional shortening (LVFS), mitral E-wave velocity-to-A-wave velocity (E:A) ratio, and ejection time were measured by use of transthoracic echocardiography. Dobutamine was administrated via a cephalic vein at rates of 2.5, 5.0, and 10 microg/kg/min.
RESULTS: Heart rate, SAP, cardiac output, and ABF increased with dobutamine administration, whereas stroke volume significantly decreased. The LVFS significantly increased, and the E:A ratio significantly decreased. Total isovolumic time and the MPI significantly decreased. The MPI was negatively correlated (r=-0.63) with LVFS. Conversely, the MPI was positively correlated with the E:A ratio (r=0.47), stroke volume (r=0.66), and total isovolumic time (r=0.95). However, the MPI was not significantly correlated with heart rate, SAP, cardiac output, or ABF. CONCLUSION AND CLINICAL RELEVANCE: Analysis suggested that the MPI provides a sensitive clinical assessment of cardiac response to medication in cats, which may be similar to the usefulness of the MPI reported in humans.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17397293     DOI: 10.2460/ajvr.68.4.385

Source DB:  PubMed          Journal:  Am J Vet Res        ISSN: 0002-9645            Impact factor:   1.156


  3 in total

1.  Vasopressor use in 41 critically ill cats (2007-2016).

Authors:  Nikki Licht; Elizabeth A Rozanski; John E Rush
Journal:  Can Vet J       Date:  2018-11       Impact factor: 1.008

2.  Repeated bedside echocardiography in children with respiratory failure.

Authors:  Jiri Kobr; Jiri Fremuth; Katerina Pizingerova; Lumir Sasek; Petr Jehlicka; Sarka Fikrlova; Zdenek Slavik
Journal:  Cardiovasc Ultrasound       Date:  2011-04-26       Impact factor: 2.062

3.  Indirect arterial blood pressure measurement in healthy anesthetized cats using a device that combines oscillometry with photoplethysmography.

Authors:  Yasuhiro Heishima; Yasutomo Hori; Seishiro Chikazawa; Kazutaka Kanai; Fumio Hoshi; Naoyuki Itoh
Journal:  J Vet Med Sci       Date:  2016-03-18       Impact factor: 1.267

  3 in total