Literature DB >> 17396658

A method of measuring Escherichia coli 0157:H7 at 1 cell/mL in 1 liter sample using antibody functionalized piezoelectric-excited millimeter-sized cantilever sensor.

Gossett A Campbell1, Raj Mutharasan.   

Abstract

Piezoelectric-excited millimeter-sized cantilever (PEMC) sensors immobilized with antibody specific to Escherichia coli (EC) 0157:H7 is used to detect EC at 1 cell/mL in 1 mL and 1 L samples in a batch and flow mode, respectively. Two sensor designs were used. The first design (PEMC-a) has both the piezoelectric and non-piezoelectric layer anchored, while in the second design (PEMC-b) had only the piezoelectric layer anchored. PEMC-a, used in batch mode with 1 mL sample, showed limit of detection at 10 cells/ mL using the second bending mode at 85.5 kHz in air. PEMC-b exhibited resonant frequencies at 186.5, 883.5, and 1778.5 kHz in air and 162.5, 800.0, and 1725.5 kHz in sample flow conditions. A one-liter sample containing 1000 EC cells was introduced at 1.5, 2.5, 3, and 17 ml/min, and the change in resonant frequency was monitored. The total frequency change observed for the mode at 800 kHz and sample flow rates of 1.5, 2.5, 3, and 17 mL/min were 2230+/-11, 3069 +/-47, 4686+/-97, and 7188+/-52 Hz, respectively. Each detection experiment was confirmed by exposing the sensor to a low pH solution followed by a phosphate buffered saline (PBS) rinse, which caused the release of the attached EC. The final frequency change observed was nearly identical to the value prior to EC attachment. Kinetic analysis showed that the observed binding rate constant at 1.5, 2.5, 3 mL/min were 0.009, 0.015, and 0.021 min(-1), respectively. The significance of these results is that very low concentration of pathogens in large sample volumes can be measured in a short time period without the need for filtration or enrichment.

Entities:  

Mesh:

Year:  2007        PMID: 17396658     DOI: 10.1021/es061947p

Source DB:  PubMed          Journal:  Environ Sci Technol        ISSN: 0013-936X            Impact factor:   9.028


  6 in total

Review 1.  Biosensors for whole-cell bacterial detection.

Authors:  Asif Ahmed; Jo V Rushworth; Natalie A Hirst; Paul A Millner
Journal:  Clin Microbiol Rev       Date:  2014-07       Impact factor: 26.132

2.  Label-free multiplexed virus detection using spectral reflectance imaging.

Authors:  Carlos A Lopez; George G Daaboul; Rahul S Vedula; Emre Ozkumur; David A Bergstein; Thomas W Geisbert; Helen E Fawcett; Bennett B Goldberg; John H Connor; M Selim Unlü
Journal:  Biosens Bioelectron       Date:  2011-01-22       Impact factor: 10.618

Review 3.  Hybrid integrated label-free chemical and biological sensors.

Authors:  Simin Mehrabani; Ashley J Maker; Andrea M Armani
Journal:  Sensors (Basel)       Date:  2014-03-26       Impact factor: 3.576

Review 4.  Review of Label-Free Monitoring of Bacteria: From Challenging Practical Applications to Basic Research Perspectives.

Authors:  Beatrix Péter; Eniko Farkas; Sandor Kurunczi; Zoltán Szittner; Szilvia Bősze; Jeremy J Ramsden; Inna Szekacs; Robert Horvath
Journal:  Biosensors (Basel)       Date:  2022-03-22

Review 5.  Recent advances in bacteriophage based biosensors for food-borne pathogen detection.

Authors:  Amit Singh; Somayyeh Poshtiban; Stephane Evoy
Journal:  Sensors (Basel)       Date:  2013-01-30       Impact factor: 3.576

Review 6.  Electrochemical Immuno- and Aptamer-Based Assays for Bacteria: Pros and Cons over Traditional Detection Schemes.

Authors:  Rimsha Binte Jamal; Stepan Shipovskov; Elena E Ferapontova
Journal:  Sensors (Basel)       Date:  2020-09-28       Impact factor: 3.576

  6 in total