Literature DB >> 17394911

In vitro effect of load cycling on metal-ceramic cement- and screw-retained implant restorations.

Matthias Karl1, Friedrich Graef, Thomas D Taylor, Siegfried M Heckmann.   

Abstract

STATEMENT OF PROBLEM: In implant prosthodontics, restorations can either be cement- or screw-retained. Aside from passivity of fit, esthetics, and retrievability, the occlusal opening of the screw-access hole (SAH) is a major difference between the 2 types of restorations. In veneered fixed partial dentures (FPDs), the SAH forms a discontinuity of the ceramic layer and may be an origin for chipping fractures.
PURPOSE: The objective of this study was to investigate whether more chipping fractures occur during dynamic loading on the occlusal surface of screw-retained ceramic-veneered implant FPDs than in cement-retained restorations.
MATERIAL AND METHODS: Ten cement-retained and 10 screw-retained ceramic veneered 5-unit FPDs were manufactured for a 3-implant situation. A masticatory simulator was used for loading the occlusal surface of the FPDs to the implant positions for 20,000 cycles with a force of 100 N applied for 1 second followed by 1 second of no loading. For analysis, 3 clinicians evaluated the FPDs using a light microscope and a dental probe. The numbers of chipping fractures found were analyzed by means of a generalized linear model with Poisson response (alpha=.05).
RESULTS: The investigators found significantly more chipping fractures in the group of screw-retained FPDs, the rate ratio of screw-retained FPDs versus cement-retained FPDs being greater than 1 with a P value of .0023.
CONCLUSION: The SAH of screw-retained implant FPDs forms a weak point of the ceramic layer.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17394911     DOI: 10.1016/j.prosdent.2007.01.001

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  9 in total

1.  Mechanical performance of cement- and screw-retained all-ceramic single crowns on dental implants.

Authors:  Matthias Obermeier; Oliver Ristow; Kurt Erdelt; Florian Beuer
Journal:  Clin Oral Investig       Date:  2017-07-15       Impact factor: 3.573

2.  In vitro performance and fracture resistance of CAD/CAM-fabricated implant supported molar crowns.

Authors:  Martin Rosentritt; Sebastian Hahnel; Frank Engelhardt; Michael Behr; Verena Preis
Journal:  Clin Oral Investig       Date:  2016-07-01       Impact factor: 3.573

3.  The Effects of New Design of Access Hole on Porcelain Fracture Resistance of Implant-Supported Crowns.

Authors:  Reza Derafshi; Mitra Farzin; Masoumeh Taghva; Hossein Heidary; Berivan Atashkar
Journal:  J Dent (Shiraz)       Date:  2015-03

4.  Effect of abutment modification and cement type on retention of cement-retained implant supported crowns.

Authors:  Mitra Farzin; Kianoosh Torabi; Ahmad Hasan Ahangari; Reza Derafshi
Journal:  J Dent (Tehran)       Date:  2014-05-31

5.  Influence of abutment design on retention of metal copings cemented to implants.

Authors:  Albano Porto da Cunha; Glauco Pereira Moysés; Ana Christina Claro Neves; Rafael Pino Vitti; Flávia Cardoso da Rosa Goulart; Laís Regiane da Siva-Concílio
Journal:  Acta Biomater Odontol Scand       Date:  2016-01-26

6.  Comparison of porcelain veneer fracture in implant-supported fixed full-arch prostheses with a framework of either titanium, cobalt-chromium, or zirconia: An in vitro study.

Authors:  Märta Vahnström; Petra H Johansson; Per Svanborg; Victoria F Stenport
Journal:  Clin Exp Dent Res       Date:  2022-03-21

7.  The effect of aging on the fracture resistance of different types of screw-cement-retained implant-supported zirconia-based restorations.

Authors:  Safoora Sahebi; Rashin Giti; Arian Sherafati
Journal:  PLoS One       Date:  2022-06-24       Impact factor: 3.752

8.  A Special Design to Facilitate Retrieval of Cement-Retained Zirconia-Based Implant-Supported Restorations.

Authors:  Mitra Farzin; Reza Derafshi; Rashin Giti; Masumeh Taghva
Journal:  J Dent (Shiraz)       Date:  2021-06

9.  Effect of screw access hole preparation on fracture load of implant-supported zirconia-based crowns: an in vitro study.

Authors:  Hadi Mokhtarpour; Reza Eftekhar Ashtiani; Minoo Mahshid; Farhad Tabatabaian; Marzieh Alikhasi
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2016-08-17
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.