Literature DB >> 17393194

CT fluoroscopy: novel application for the treatment of ventricular pathologies.

Kieran Murphy1, David A Nussbaum, Philippe Gailloud.   

Abstract

INTRODUCTION: Recent advances in multidetector CT imaging (MDCT) provide real-time "fluoroscopic-like" capabilities with excellent spatial resolution. MDCT fluoroscopy expands our ability to perform image-guided interventions in anatomically complex locations. Although MDCT fluoroscopy is currently used at our institution for a variety of procedures ranging from spinal nerve blocks to RFA ablation, we believe these same techniques can be used to navigate within the ventricles of the central nervous system to treat conditions requiring placement of intraventricular catheters, depth electrodes, or potentially stents for the relief of CSF outlet obstruction.
METHODS: Using three fresh, unfrozen human cadavers, we studied the feasibility of using MDCT fluoroscopy for intraventricular catheter placement and to stent the aqueduct of Sylvius.
RESULTS: The ventricles were entered via a single needle pass and catheters were placed over the wire. Contrast agent was then injected to visualize the distribution. To stent the aqueduct of Sylvius, a wire was passed into the 4th ventricle and a coronary stent was then inserted over the wire and deployed.
CONCLUSION: Based on our success with these procedures, we believe this technique can be used to limit complications and improve efficacy of a number of neurosurgical procedures.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17393194     DOI: 10.1007/s00234-007-0208-2

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  23 in total

1.  Radiation exposures to patients from CT: reality, public perception, and policy.

Authors:  E L Nickoloff; P O Alderson
Journal:  AJR Am J Roentgenol       Date:  2001-08       Impact factor: 3.959

Review 2.  Current status of stereotactic biopsy.

Authors:  V Rajshekhar
Journal:  Stereotact Funct Neurosurg       Date:  2001       Impact factor: 1.875

3.  Evaluation of minimally invasive percutaneous CT-controlled ventriculostomy in patients with severe head trauma.

Authors:  M Krötz; U Linsenmaier; K G Kanz; K J Pfeifer; W Mutschler; M Reiser
Journal:  Eur Radiol       Date:  2003-11-06       Impact factor: 5.315

Review 4.  Chronic subdural collection after endoscopic third ventriculostomy.

Authors:  E Sgaramella; G Castelli; S Sotgiu
Journal:  Acta Neurochir (Wien)       Date:  2004-04-08       Impact factor: 2.216

5.  Benefits and safety of CT fluoroscopy in interventional radiologic procedures.

Authors:  S K Carlson; C E Bender; K L Classic; F E Zink; J P Quam; E M Ward; A L Oberg
Journal:  Radiology       Date:  2001-05       Impact factor: 11.105

6.  MRimaging findings after ventricular puncture in patients with SAH.

Authors:  J Tominaga; M Shimoda; S Oda; A Kumasaka; K Yamazaki; R Tsugane
Journal:  Acta Neurochir (Wien)       Date:  2001-11       Impact factor: 2.216

7.  Endoscopic third ventriculostomy for hydrocephalus secondary to central nervous system infection or intraventricular hemorrhage in children.

Authors:  Matthew D Smyth; R Shane Tubbs; John C Wellons; W Jerry Oakes; Jeffrey P Blount; Paul A Grabb
Journal:  Pediatr Neurosurg       Date:  2003-11       Impact factor: 1.162

8.  Neuroendoscopy: one year of experience--personal results, observations and limits.

Authors:  E Sgaramella; S Sotgiu; F M Crotti
Journal:  Minim Invasive Neurosurg       Date:  2003-08

9.  Fine-needle aspiration biopsy of the central nervous system performed freehand under computed tomography guidance without stereotactic instrumentation.

Authors:  Rania M Seliem; Margaret W Assaad; Steve J Gorombey; Luis A Moral; J Robert Kirkwood; Christopher N Otis
Journal:  Cancer       Date:  2003-10-25       Impact factor: 6.860

10.  Image-guided percutaneous radiofrequency ablation for osteoid osteomas.

Authors:  Anthony C Venbrux; Brian J Montague; Kieran P J Murphy; Lauren A Bobonis; Stanley B Washington; Amy P Soltes; Frank J Frassica
Journal:  J Vasc Interv Radiol       Date:  2003-03       Impact factor: 3.464

View more
  2 in total

1.  CT Fluoroscopy-guided Aspiration of Intracerebral Hematomas: Technique and Outcomes.

Authors:  Kihwan Hwang; Gyojun Hwang; O-Ki Kwon; Jae Seung Bang; Chang Wan Oh
Journal:  J Cerebrovasc Endovasc Neurosurg       Date:  2015-03-31

2.  Image quality improvement in cone-beam CT using the super-resolution technique.

Authors:  Asuka Oyama; Shinobu Kumagai; Norikazu Arai; Takeshi Takata; Yusuke Saikawa; Kenshiro Shiraishi; Takenori Kobayashi; Jun'ichi Kotoku
Journal:  J Radiat Res       Date:  2018-07-01       Impact factor: 2.724

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.