Literature DB >> 17389960

Vascular mimetics based on microfluidics for imaging the leukocyte--endothelial inflammatory response.

Ulrich Y Schaff1, Malcolm M Q Xing, Kathleen K Lin, Ning Pan, Noo Li Jeon, Scott I Simon.   

Abstract

We describe the development, validation, and application of a novel PDMS-based microfluidic device for imaging leukocyte interaction with a biological substrate at defined shear force employing a parallel plate geometry that optimizes experimental throughput while decreasing reagent consumption. The device is vacuum bonded above a standard 6-well tissue culture plate that accommodates a monolayer of endothelial cells, thereby providing a channel to directly observe the kinetics of leukocyte adhesion under defined shear flow. Computational fluid dynamics (CFD) was applied to model the shear stress and the trajectory of leukocytes within the flow channels at a micron length scale. In order to test this model, neutrophil capture, rolling, and deceleration to arrest as a function of time and position was imaged in the transparent channels. Neutrophil recruitment to the substrate proved to be highly sensitive to disturbances in flow streamlines, which enhanced the rate of neutrophil-surface collisions at the entrance to the channels. Downstream from these disturbances, the relationship between receptor mediated deceleration of rolling neutrophils and dose response of stimulation by the chemokine IL-8 was found to provide a functional readout of integrin activation. This microfluidic technique allows detailed kinetic studies of cell adhesion and reveals neutrophil activation within seconds to chemotactic molecules at concentrations in the picoMolar range.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17389960     DOI: 10.1039/b617915k

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  53 in total

1.  Migrational guidance of neutrophils is mechanotransduced via high-affinity LFA-1 and calcium flux.

Authors:  Neha Dixit; Itsukyo Yamayoshi; Ari Nazarian; Scott I Simon
Journal:  J Immunol       Date:  2011-06-01       Impact factor: 5.422

Review 2.  Biomechanics of leukocyte rolling.

Authors:  Prithu Sundd; Maria K Pospieszalska; Luthur Siu-Lun Cheung; Konstantinos Konstantopoulos; Klaus Ley
Journal:  Biorheology       Date:  2011       Impact factor: 1.875

3.  Three-dimensional fit-to-flow microfluidic assembly.

Authors:  Arnold Chen; Tingrui Pan
Journal:  Biomicrofluidics       Date:  2011-12-14       Impact factor: 2.800

4.  Fluid shear stress primes mouse embryonic stem cells for differentiation in a self-renewing environment via heparan sulfate proteoglycans transduction.

Authors:  Yi-Chin Toh; Joel Voldman
Journal:  FASEB J       Date:  2010-12-23       Impact factor: 5.191

5.  Coaxial flow system for chemical cytometry.

Authors:  Paul J Marc; Christopher E Sims; Nancy L Allbritton
Journal:  Anal Chem       Date:  2007-11-03       Impact factor: 6.986

6.  On-chip evaluation of neutrophil activation and neutrophil-endothelial cell interaction during neutrophil chemotaxis.

Authors:  Donghyuk Kim; Christy L Haynes
Journal:  Anal Chem       Date:  2013-10-28       Impact factor: 6.986

7.  Design, fabrication and implementation of a novel multi-parameter control microfluidic platform for three-dimensional cell culture and real-time imaging.

Authors:  Vernella Vickerman; Jennifer Blundo; Seok Chung; Roger Kamm
Journal:  Lab Chip       Date:  2008-07-18       Impact factor: 6.799

8.  Microfluidic devices for studies of shear-dependent platelet adhesion.

Authors:  Edgar Gutierrez; Brian G Petrich; Sanford J Shattil; Mark H Ginsberg; Alex Groisman; Ana Kasirer-Friede
Journal:  Lab Chip       Date:  2008-07-23       Impact factor: 6.799

9.  Orai1 regulates intracellular calcium, arrest, and shape polarization during neutrophil recruitment in shear flow.

Authors:  Ulrich Y Schaff; Neha Dixit; Emily Procyk; Itsukyo Yamayoshi; Tiffany Tse; Scott I Simon
Journal:  Blood       Date:  2009-11-20       Impact factor: 22.113

10.  On-chip endothelial inflammatory phenotyping.

Authors:  J Sherrod DeVerse; Keith A Bailey; Greg A Foster; Vaishali Mittal; Stuart M Altman; Scott I Simon; Anthony G Passerini
Journal:  J Vis Exp       Date:  2012-07-21       Impact factor: 1.355

View more