Literature DB >> 17386750

Direct electrochemistry of glucose oxidase entrapped in nano gold particles-ionic liquid-N,N-dimethylformamide composite film on glassy carbon electrode and glucose sensing.

Jiangwen Li1, Jingjing Yu, Faqiong Zhao, Baizhao Zeng.   

Abstract

The direct electrochemistry of glucose oxidase (GOD) entrapped in nano gold particles (NAs)-N,N-dimethylformamide (DMF)-1-butyl-3-methylimidazolium hexafluophosphate (BMIMPF(6)) composite film on a glassy carbon electrode (NAs-DMF-GOD (BMIMPF(6))/GC) has been investigated for first time. The immobilized GOD exhibits a pair of well-defined reversible peaks in 0.050 M pH 5 phosphate solutions (PS), resulting from the redox of flavin adenine dinucleotide (FAD) in GOD. The peak currents are three times as large as those of GOD-NAs-DMF film coated GC electrode (i.e. NAs-DMF-GOD (water)/GC). In addition, the NAs-DMF-GOD (BMIMPF(6)) composite material has higher thermal stability than NAs-DMF-GOD (water). Results show that ionic liquid BMIMPF(6), DMF and NAs are requisite for GOD to exhibit a pair of stable and reversible peaks. Without any of them, the peaks of GOD become small and unstable. Upon the addition of glucose, the peak currents of GOD decrease and a new cathodic peak occurs at -0.8 V (versus SCE), which corresponds to the reduction of hydrogen peroxide (H(2)O(2)) generated by the catalytic oxidation of glucose. The peak current of the new cathodic peak and the glucose concentration show a linear relationship in the ranges of 1.0 x 10(-7) to 1.0 x 10(-6)M and 2.0 x 10(-6) to 2.0 x 10(-5) M. The kinetic parameter I(max) of H(2)O(2) is estimated to be 1.19 x 10(-6)A and the apparent K(m) (Michaelis-Menten constant) for the enzymatic reaction is 3.49 microM. This method has been successfully applied to the determination of glucose in human plasma and beer samples, and the average recoveries are 97.2% and 99%, respectively.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17386750     DOI: 10.1016/j.aca.2007.01.014

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  6 in total

1.  Enhanced peroxidase-like activity of platinum nanoparticles decorated on nickel- and nitrogen-doped graphene nanotubes: colorimetric detection of glucose.

Authors:  Neda Fakhri; Foad Salehnia; Sepideh Mohammad Beigi; Sajjad Aghabalazadeh; Morteza Hosseini; Mohammad Reza Ganjali
Journal:  Mikrochim Acta       Date:  2019-05-28       Impact factor: 5.833

2.  Evaluation of luminol chemiluminescence based on simultaneous introducing of coumarin derivatives as green fluorophores and chitosan-induced Au/Ag alloy nanoparticle as catalyst for the sensitive determination of glucose.

Authors:  M J Chaichi; S O Alijanpour; S Asghari; S Shadlou
Journal:  J Fluoresc       Date:  2015-02-03       Impact factor: 2.217

Review 3.  Electrochemical Sensors for Clinic Analysis.

Authors:  You Wang; Hui Xu; Jianming Zhang; Guang Li
Journal:  Sensors (Basel)       Date:  2008-03-27       Impact factor: 3.576

Review 4.  Electrochemical glucose sensors--developments using electrostatic assembly and carbon nanotubes for biosensor construction.

Authors:  Alice Harper; Mark R Anderson
Journal:  Sensors (Basel)       Date:  2010-09-02       Impact factor: 3.576

5.  Fabrication of a Multi-Walled Nanotube (MWNT) Ionic Liquid Electrode and Its Application for Sensing Phenolics in Red Wines.

Authors:  Kyo-Il Kim; Hee-Young Kang; Jae-Chan Lee; Seong-Ho Choi
Journal:  Sensors (Basel)       Date:  2009-08-26       Impact factor: 3.576

Review 6.  Recent Advances in Ionic Liquids in Biomedicine.

Authors:  Alexander M Curreri; Samir Mitragotri; Eden E L Tanner
Journal:  Adv Sci (Weinh)       Date:  2021-07-10       Impact factor: 16.806

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.