Literature DB >> 17386705

Multi-detection of corticosteroids in sports doping and veterinary control using high-resolution liquid chromatography/time-of-flight mass spectrometry.

M E Touber1, M C van Engelen, C Georgakopoulus, J A van Rhijn, M W F Nielen.   

Abstract

A liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS) method was developed using the latest high-resolution LC column technology, the ultra performance liquid chromatography (UPLC), and electrospray ionization (ESI) in the positive ion mode. Gradient UPLC separation conditions were optimized for a group of 22 analytes comprising 17 glucocorticosteroids, specific designer steroids such as tetrahydrogestrinone (THG) and specific beta2-agonists such as formoterol. The UPLC/TOFMS separation obtained required 5.5 min only for all the substances tested. Even the critical pair of dexamethasone and betamethasone isomers was almost completely resolved. Thanks to the over 10,000 full-width at half maximum (FWHM) mass resolution and high mass accuracy features of TOFMS 50 mDa window accurate mass chromatograms could be reconstructed for the individual analytes. Sensitive screening in human and calf urine samples fortified at the glucocorticosteroids minimum required performance limit (MRPL) of 30 microg L(-1) (human urine, sports doping) and 2 microg L(-1) (calf urine, veterinary control) could be obtained. The potential of UPLC/TOFMS for confirmatory analysis was shown by determining the accurate mass of all compounds and fragment ions upon in-source collision-induced dissociation (CID) at different energies. The exact mass measurement errors for all glucocorticosteroids were found to be within 6 ppm. Considering veterinary control, limits of detection (LOD) and limits of quantification (LOQ) were determined for most of the analytes in calf urine and found to range from 0.1 to 3.3 and from 0.4 to 4.4 microg L(-1), respectively. The method can be easily extended with other banned substances of interest, as demonstrated by the addition of 21 beta2-agonists to the original analyte mixture in urine, without causing any interferences.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17386705     DOI: 10.1016/j.aca.2006.09.058

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  4 in total

1.  Automated sub-ppm mass accuracy on an ESI-TOF for use with drug discovery compound libraries.

Authors:  Justin G Stroh; Christopher J Petucci; Scott J Brecker; Nelson Huang; James M Lau
Journal:  J Am Soc Mass Spectrom       Date:  2007-06-16       Impact factor: 3.109

2.  Detection and quantification of 12 anabolic steroids and analogs in human whole blood and 20 in hair using LC-HRMS/MS: application to real cases.

Authors:  Nicolas Fabresse; Stanislas Grassin-Delyle; Isabelle Etting; Jean-Claude Alvarez
Journal:  Int J Legal Med       Date:  2017-02-24       Impact factor: 2.686

3.  Generic sample preparation combined with high-resolution liquid chromatography-time-of-flight mass spectrometry for unification of urine screening in doping-control laboratories.

Authors:  R J B Peters; J E Oosterink; A A M Stolker; C Georgakopoulos; M W F Nielen
Journal:  Anal Bioanal Chem       Date:  2010-02-16       Impact factor: 4.142

4.  Application of LC-MS/MS for quantitative analysis of glucocorticoids and stimulants in biological fluids.

Authors:  Jamshed Haneef; Mohammad Shaharyar; Asif Husain; Mohd Rashid; Ravinesh Mishra; Shama Parveen; Niyaz Ahmed; Manoj Pal; Deepak Kumar
Journal:  J Pharm Anal       Date:  2013-04-02
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.