| Literature DB >> 17386702 |
S Biddle1, P Teale, A Robinson, J Bowman, E Houghton.
Abstract
A novel analytical approach has been developed and shown to be capable of detecting the isomers of oestradiol in the low ppt (pg mL(-1)) range in bovine serum and urine. Following extractive derivatisation the analytes were detected as their 3-pentafluorobenzoyl 17-trimethylsilyl ether derivatives by gas chromatography-mass spectrometry/mass spectrometry (GC-MS/MS), using electron capture negative ion chemical ionisation. The isomers of oestradiol were quantified in both blank and post-administration urine and serum samples, with a view to setting action/threshold levels for these compounds, to allow discrimination between normal samples and samples from animals treated with growth promoting ear implants. A non-parametric statistical assessment of the data resulted in proposed action levels (with a false positive probability of 1 in 1000) of 1.6 and 2.7 ng mL(-1) for 17alpha-oestradiol, in male and female urine, respectively, and 40 and 44 pg mL(-1) for 17beta-oestradiol, in male and female urine, respectively. An action level of 20 pg mL(-1) was proposed for 17alpha- and 17beta-oestradiol in male serum. In female serum the proposed action levels were 40 and 20 pg mL(-1) for 17alpha- and 17beta-oestradiol, respectively.Entities:
Mesh:
Substances:
Year: 2006 PMID: 17386702 DOI: 10.1016/j.aca.2006.10.044
Source DB: PubMed Journal: Anal Chim Acta ISSN: 0003-2670 Impact factor: 6.558