Literature DB >> 17386544

Simultaneous detection of ascorbate and uric acid using a selectively catalytic surface.

Hossam M Nassef1, Abd-Elgawad Radi, Ciara O'Sullivan.   

Abstract

The direct and selective detection of ascorbate at conventional carbon or metal electrodes is difficult due to its large overpotential and fouling by oxidation products. Electrode modification by electrochemical reduction of diazonium salts of different aryl derivatives is useful for catalytic, analytical and biotechnological applications. A monolayer of o-aminophenol (o-AP) was grafted on a glassy carbon electrode (GCE) via the electrochemical reduction of its in situ prepared diazonium salts in aqueous solution. The o-aminophenol confined surface was characterized by cyclic voltammetry. The grafted film demonstrated an excellent electrocatalytic activity towards the oxidation of ascorbate in phosphate buffer of pH 7.0 shifting the overpotential from +462 to +263 mV versus Ag/AgCl. Cyclic voltammetry and d.c. amperometric measurements were carried out for the quantitative determination of ascorbate and uric acid. The catalytic oxidation peak current was linearly dependent on the ascorbate concentration and a linear calibration curve was obtained using d.c. amperometry in the range of 2-20 microM of ascorbate with a correlation coefficient 0.9998, and limit of detection 0.3 microM. The effect of H2O2 on the electrocatalytic oxidation of ascorbate at o-aminophenol modified GC electrode has been studied, the half-life time and rate constant was estimated as 270 s, and 2.57x10(-3) s(-1), respectively. The catalytically selective electrode was applied to the simultaneous detection of ascorbate and uric acid, and used for their determination in real urine samples. This o-AP/GCE showed high stability with time, and was used as a simple and precise amperometric sensor for the selective determination of ascorbate.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17386544     DOI: 10.1016/j.aca.2006.10.004

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  2 in total

1.  Integrated carbon fiber electrodes within hollow polymer microneedles for transdermal electrochemical sensing.

Authors:  Philip R Miller; Shaun D Gittard; Thayne L Edwards; Deanna M Lopez; Xiaoyin Xiao; David R Wheeler; Nancy A Monteiro-Riviere; Susan M Brozik; Ronen Polsky; Roger J Narayan
Journal:  Biomicrofluidics       Date:  2011-03-30       Impact factor: 2.800

Review 2.  Electrochemical Sensors for Clinic Analysis.

Authors:  You Wang; Hui Xu; Jianming Zhang; Guang Li
Journal:  Sensors (Basel)       Date:  2008-03-27       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.