Literature DB >> 17386477

Application of a validated stability-indicating densitometric thin-layer chromatographic method to stress degradation studies on moxifloxacin.

Sanjay K Motwani1, Roop K Khar, Farhan J Ahmad, Shruti Chopra, K Kohli, S Talegaonkar.   

Abstract

A simple, sensitive, selective, precise and stability-indicating high-performance thin-layer chromatographic (HPTLC) method for densitometric determination of moxifloxacin both as a bulk drug and from pharmaceutical formulation was developed and validated as per the International Conference on Harmonization (ICH) guidelines. The method employed TLC aluminium plates pre-coated with silica gel 60F-254 as the stationary phase and the mobile phase consisted of n-propanol-ethanol-6M ammonia solution (4:1:2, v/v/v). Densitometric analysis of moxifloxacin was carried out in the absorbance mode at 298 nm. Compact spots for moxifloxacin were found at R(f) value of 0.58+/-0.02. The linear regression analysis data for the calibration plots showed good linear relationship with r=0.9925 in the working concentration range of 100-800 ng spot(-1). The method was validated for precision, accuracy, ruggedness, robustness, specificity, recovery, limit of detection (LOD) and limit of quantitation (LOQ). The LOD and LOQ were 3.90 and 11.83 ng spot(-1), respectively. Drug was subjected to acid and alkali hydrolysis, oxidation, dry heat, wet heat treatment and photodegradation. All the peaks of degradation products were well resolved from the standard drug with significantly different R(f) values. Statistical analysis proves that the developed HPTLC method is reproducible and selective. As the method could effectively separate the drug from its degradation products, it can be employed as stability-indicating one. Moreover, the proposed HPTLC method was utilized to investigate the kinetics of the acidic and alkaline degradation processes at different temperatures. Arrhenius plot was constructed and apparent pseudo-first-order rate constant, half-life and activation energy were calculated. In addition the pH-rate profile for degradation of moxifloxacin in constant ionic strength buffer solutions within the pH range 1.2-10.8 was studied.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17386477     DOI: 10.1016/j.aca.2006.08.053

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  2 in total

1.  Photodegradation of moxifloxacin in aqueous and organic solvents: a kinetic study.

Authors:  Iqbal Ahmad; Raheela Bano; Syed Ghulam Musharraf; Sofia Ahmed; Muhammad Ali Sheraz; Qamar ul Arfeen; Muhammad Salman Bhatti; Zufi Shad
Journal:  AAPS PharmSciTech       Date:  2014-08-20       Impact factor: 3.246

2.  Development and validation of spectrophotometric, atomic absorption and kinetic methods for determination of moxifloxacin hydrochloride.

Authors:  Lobna M Abdellaziz; Mervat M Hosny
Journal:  Anal Chem Insights       Date:  2011-11-07
  2 in total