Literature DB >> 17385746

Enzyme-linked immunosorbent assay of Escherichia coli O157:H7 in surface enhanced poly(methyl methacrylate) microchannels.

Yunling Bai1, Wei-Cho Huang, Shang-Tian Yang.   

Abstract

A novel surface treatment method was developed to enhance polymer-based microchannel enzyme-linked immunosorbent assay (ELISA) for Escherichia coli O157:H7 detection. By applying an amine-bearing polymer, poly(ethyleneimine) (PEI), onto poly(methyl methacrylate) (PMMA) surface at pH higher than 11, PEI molecules were covalently attached and their amine groups were introduced to PMMA surface. Zeta potential analysis and X-ray photoelectron spectroscopy (XPS) demonstrated that the alkali condition is preferable for PEI attachment onto the PMMA surface. The amine groups on the PMMA surface were then functionalized with glutaraldehyde, whose aldehyde groups served as the active sites for binding the antibody by forming covalent bonds with the amine groups of the protein molecules. This surface modification greatly improved antibody binding efficiency and the microchannel ELISA for E. coli O157:H7 detection. Compared with untreated PMMA microchannels, approximately 45 times higher signal and 3 times higher signal/noise ratio were achieved with the PEI surface treatment, which also shortened the time required for cells to bind to the microchannel surface to approximately 2 min, much less than that usually required for the same ELISA carried out in 96-well plates. The detection in the microchannel ELISA only required 5-8 cells per sample, which is also better than 15-30 cells required in multi-well plates. With the high sensitivity, short assay time, and small reagent consumption, the microchannel ELISA can be economically used for fast detection of E. coli O157:H7. (c) 2007 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17385746     DOI: 10.1002/bit.21429

Source DB:  PubMed          Journal:  Biotechnol Bioeng        ISSN: 0006-3592            Impact factor:   4.530


  4 in total

1.  The Development of a Portable SPR Bioanalyzer for Sensitive Detection of Escherichia coli O157:H7.

Authors:  Shun Wang; Jiufeng Xie; Min Jiang; Keke Chang; Ruipeng Chen; Liuzheng Ma; Juanhua Zhu; Qingqian Guo; Haifeng Sun; Jiandong Hu
Journal:  Sensors (Basel)       Date:  2016-11-04       Impact factor: 3.576

2.  Enhanced detection sensitivity of Escherichia coli O157:H7 using surface-modified gold nanorods.

Authors:  Mohankandhasamy Ramasamy; Dong Kee Yi; Seong Soo A An
Journal:  Int J Nanomedicine       Date:  2015-08-27

3.  Patterned immobilization of antibodies within roll-to-roll hot embossed polymeric microfluidic channels.

Authors:  Belachew Feyssa; Christina Liedert; Liisa Kivimaki; Leena-Sisko Johansson; Heli Jantunen; Leena Hakalahti
Journal:  PLoS One       Date:  2013-07-18       Impact factor: 3.240

4.  Screen Printed Based Impedimetric Immunosensor for Rapid Detection of Escherichia coli in Drinking Water.

Authors:  Martina Cimafonte; Andrea Fulgione; Rosa Gaglione; Marina Papaianni; Rosanna Capparelli; Angela Arciello; Sergio Bolletti Censi; Giorgia Borriello; Raffaele Velotta; Bartolomeo Della Ventura
Journal:  Sensors (Basel)       Date:  2020-01-03       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.