Literature DB >> 17385227

Initial cytotoxicity of novel titanium alloys.

M Koike1, P E Lockwood, J C Wataha, T Okabe.   

Abstract

We assessed the biological response to several novel titanium alloys that have promising physical properties for biomedical applications. Four commercial titanium alloys [Super-TIX(R) 800, Super-TIX(R) 51AF, TIMETAL(R) 21SRx, and Ti-6Al-4V (ASTM grade 5)] and three experimental titanium alloys [Ti-13Cr-3Cu, Ti-1.5Si and Ti-1.5Si-5Cu] were tested. Specimens (n = 6; 5.0 x 5.0 x 3.0 mm(3)) were cast in a centrifugal casting machine using a MgO-based investment and polished to 600 grit, removing 250 mum from each surface. Commercially pure titanium (CP Ti: ASTM grade 2) and Teflon (polytetrafluoroethylene) were used as positive controls. The specimens were cleaned and disinfected, and then each cleaned specimen was placed in direct contact with Balb/c 3T3 fibroblasts for 72 h. The cytotoxicity [succinic dehydrogenase (SDH) activity] of the extracts was assessed using the MTT method. Cytotoxicity of the metals tested was not statistically different compared to the CP Ti and Teflon controls (p > 0.05). These novel titanium alloys pose cytotoxic risks no greater than many other commonly used alloys, including commercially pure titanium. The promising short-term biocompatibility of these Ti alloys is probably due to their excellent corrosion resistance under static conditions, even in biological environments.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17385227     DOI: 10.1002/jbm.b.30799

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  3 in total

1.  In vitro biocompatibility of orthodontic miniscrews with human gingival fibroblast and SAOS-2 osteoblast cultures.

Authors:  Hannah Finke; Bernd Koos; Helge Fischer-Brandies; Martha Es-Souni
Journal:  J Orofac Orthop       Date:  2018-07-16       Impact factor: 1.938

2.  Biomechanical evaluations of the long-term stability of dental implant using finite element modeling method: a systematic review.

Authors:  Seyed Aref Hosseini-Faradonbeh; Hamid Reza Katoozian
Journal:  J Adv Prosthodont       Date:  2022-06-27       Impact factor: 1.989

3.  The effect of platform switching on the levels of metal ion release from different implant-abutment couples.

Authors:  Ghada O Alrabeah; Jonathan C Knowles; Haralampos Petridis
Journal:  Int J Oral Sci       Date:  2016-06-30       Impact factor: 6.344

  3 in total