Abstract

Balloon angioplasty intervention is traumatic to arterial tissue. Fracture mechanisms such as plaque fissuring and/or dissection occur and constitute major contributions to the lumen enlargement. However, these types of mechanically-based traumatization of arterial tissue are also contributing factors to both acute procedural complications and chronic restenosis of the treatment site. We propose physical and finite element models, which are generally useable to trace fissuring and/or dissection in atherosclerotic plaques during balloon angioplasty interventions. The arterial wall is described as an anisotropic, heterogeneous, highly deformable, nearly incompressible body, whereas tissue failure is captured by a strong discontinuity kinematics and a novel cohesive zone model. The numerical implementation is based on the partition of unity finite element method and the interface element method. The later is used to link together meshes of the different tissue components. The balloon angioplasty-based failure mechanisms are numerically studied in 3D by means of an atherosclerotic-prone human external iliac artery, with a type V lesion. Image-based 3D geometry is generated and tissue-specific material properties are considered. Numerical results show that in a primary phase the plaque fissures at both shoulders of the fibrous cap and stops at the lamina elastica interna. In a secondary phase, local dissections between the intima and the media develop at the fibrous cap location with the smallest thickness. The predicted results indicate that plaque fissuring and dissection cause localized mechanical trauma, but prevent the main portion of the stenosis from high stress, and hence from continuous tissue damage.

Entities:  

Mesh:

Year:  2007        PMID: 17385047     DOI: 10.1007/s10439-007-9258-1

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  10 in total

1.  Crack Propagation Versus Fiber Alignment in Collagen Gels: Experiments and Multiscale Simulation.

Authors:  Sarah M Vanderheiden; Mohammad F Hadi; V H Barocas
Journal:  J Biomech Eng       Date:  2015-12       Impact factor: 2.097

2.  Numerical modeling of experimental human fibrous cap delamination.

Authors:  Xiaochang Leng; Lindsey A Davis; Xiaomin Deng; Michael A Sutton; Susan M Lessner
Journal:  J Mech Behav Biomed Mater       Date:  2016-02-10

3.  Numerical simulation of arterial dissection during balloon angioplasty of atherosclerotic coronary arteries.

Authors:  Pierre Badel; Stéphane Avril; Michael A Sutton; Susan M Lessner
Journal:  J Biomech       Date:  2014-01-14       Impact factor: 2.712

4.  Effects of stent design and atherosclerotic plaque composition on arterial wall biomechanics.

Authors:  Lucas H Timmins; Clark A Meyer; Michael R Moreno; James E Moore
Journal:  J Endovasc Ther       Date:  2008-12       Impact factor: 3.487

5.  Simple model of atherosclerosis in cylindrical arteries: impact of anisotropic growth on Glagov remodeling.

Authors:  Navid Mohammad Mirzaei; Pak-Wing Fok
Journal:  Math Med Biol       Date:  2021-03-15       Impact factor: 1.854

6.  Artery buckling affects the mechanical stress in atherosclerotic plaques.

Authors:  Arnav Sanyal; Hai-Chao Han
Journal:  Biomed Eng Online       Date:  2015-01-09       Impact factor: 2.819

7.  Competition between cap and basal actin fiber orientation in cells subjected to contact guidance and cyclic strain.

Authors:  Chiara Tamiello; Carlijn V C Bouten; Frank P T Baaijens
Journal:  Sci Rep       Date:  2015-03-04       Impact factor: 4.379

8.  Simulation of stent deployment in a realistic human coronary artery.

Authors:  Frank J H Gijsen; Francesco Migliavacca; Silvia Schievano; Laura Socci; Lorenza Petrini; Attila Thury; Jolanda J Wentzel; Anton F W van der Steen; Patrick W S Serruys; Gabriele Dubini
Journal:  Biomed Eng Online       Date:  2008-08-06       Impact factor: 2.819

9.  The influence of computational strategy on prediction of mechanical stress in carotid atherosclerotic plaques: comparison of 2D structure-only, 3D structure-only, one-way and fully coupled fluid-structure interaction analyses.

Authors:  Yuan Huang; Zhongzhao Teng; Umar Sadat; Martin J Graves; Martin R Bennett; Jonathan H Gillard
Journal:  J Biomech       Date:  2014-01-21       Impact factor: 2.712

10.  Numerical model of a valvuloplasty balloon: in vitro validation in a rapid-prototyped phantom.

Authors:  Benedetta Biffi; Giorgia M Bosi; Valentina Lintas; Rod Jones; Spyros Tzamtzis; Gaetano Burriesci; Francesco Migliavacca; Andrew M Taylor; Silvia Schievano; Giovanni Biglino
Journal:  Biomed Eng Online       Date:  2016-04-12       Impact factor: 2.819

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.