Literature DB >> 17383321

Long-term follow-up of ultraflex metallic stents in benign and malignant central airway obstruction.

Syed A Husain1, David Finch, Manzoor Ahmed, Anthony Morgan, Martin R Hetzel.   

Abstract

BACKGROUND: We report experience with Ultraflex metallic stents (Boston Scientific, Natick, MA) inserted at rigid bronchoscopy under general anesthesia for palliation of benign and malignant upper airway obstruction.
METHODS: Notes of all patients treated with Ultraflex stents from 1999 to 2003 were reviewed for symptomatic response, spirometric data, and any complications before discharge home. Long-term outcome was assessed by questionnaires sent to patients' general practitioners.
RESULTS: Recruited were 66 patients (12 benign, 54 malignant airway obstructions). Before discharge home, breathlessness improved in 11 of 12 patients with benign obstruction and in 39 of 54 with malignancies. Postoperative complications in 10 patients with malignant obstructions and in 2 patients with benign obstruction were successfully controlled. It was not possible to perform preoperative pulmonary function tests in most of the patients who presented as emergencies. Mean improvement in forced expiratory volume in 1 second was 0.88 liters in 3 patients with benign obstruction and 0.28 liters in 14 patients with malignant obstruction, and mean peak expiratory flow rate improved by 109 L/min and 97 L/min, respectively. General practitioners completed questionnaires for 12 benign patients and 46 of 54 patients with malignancies. At a mean follow-up of 1017 days (range, 46 to 1120 days), 10 of the 12 patients with benign disease were alive and 7 of 46 patients with malignant airway obstruction were alive, with a median survival of 128 days (mean, 361; range, 3 to 1859 days). Most survivors had Medical Research Council grade III breathlessness or better, with few stent-related symptoms.
CONCLUSIONS: Ultraflex stents proved safe and effective in prolonged palliation of benign and malignant airways obstruction.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17383321     DOI: 10.1016/j.athoracsur.2006.11.066

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  25 in total

Review 1.  Magnetic resonance imaging of patients with airway stents.

Authors:  Yang Xia; Rui Jin; Wen Li; Huahao Shen
Journal:  J Thorac Dis       Date:  2018-10       Impact factor: 2.895

2.  Obstruction of the right stem bronchus due to ovarian local metastasis: a 5-year follow-up.

Authors:  Ilias Karapantzos; Paul Zarogoulidis; Michail Karanikas; Vasilis Thomaidis; Charalampos Charalampidis; Chrysa Karapantzou
Journal:  Ann Transl Med       Date:  2016-11

Review 3.  Techniques of endoscopic airway tumor treatment.

Authors:  Nicolas Guibert; Laurent Mhanna; Sylvain Droneau; Gavin Plat; Alain Didier; Julien Mazieres; Christophe Hermant
Journal:  J Thorac Dis       Date:  2016-11       Impact factor: 2.895

4.  Complications Following Therapeutic Bronchoscopy for Malignant Central Airway Obstruction: Results of the AQuIRE Registry.

Authors:  David E Ost; Armin Ernst; Horiana B Grosu; Xiudong Lei; Javier Diaz-Mendoza; Mark Slade; Thomas R Gildea; Michael Machuzak; Carlos A Jimenez; Jennifer Toth; Kevin L Kovitz; Cynthia Ray; Sara Greenhill; Roberto F Casal; Francisco A Almeida; Momen Wahidi; George A Eapen; Lonny B Yarmus; Rodolfo C Morice; Sadia Benzaquen; Alain Tremblay; Michael Simoff
Journal:  Chest       Date:  2015-08       Impact factor: 9.410

5.  COMPARISON OF FLUOROSCOPY AND COMPUTED TOMOGRAPHY FOR TRACHEAL LUMEN DIAMETER MEASUREMENT AND DETERMINATION OF INTRALUMINAL STENT SIZE IN HEALTHY DOGS.

Authors:  Jackie M Williams; Ingar A Krebs; Elizabeth A Riedesel; Qianqian Zhao
Journal:  Vet Radiol Ultrasound       Date:  2016-01-19       Impact factor: 1.363

6.  Is there a beneficial role for a flexible bronchoscopic approach to oesophageal tumour-related tracheobronchial stenosis?

Authors:  Emmet E McGrath; David Warriner; Paul Anderson
Journal:  Lung       Date:  2011-06-19       Impact factor: 2.584

7.  Respiratory infections increase the risk of granulation tissue formation following airway stenting in patients with malignant airway obstruction.

Authors:  David E Ost; Archan M Shah; Xiudong Lei; Myrna C B Godoy; Carlos A Jimenez; George A Eapen; Pushan Jani; Andrew J Larson; Mona G Sarkiss; Rodolfo C Morice
Journal:  Chest       Date:  2011-12-22       Impact factor: 9.410

8.  Is stent insertion via flexible bronchoscopy a feasible alternative to surgery in inoperable thyroid related tracheobronchial stenosis?

Authors:  Emmet E McGrath; David Warriner; Paul B Anderson
Journal:  J Thorac Dis       Date:  2013-06       Impact factor: 2.895

9.  Metallic stent insertion and removal for post-tracheotomy and post-intubation tracheal stenosis.

Authors:  Yonghua Bi; Zepeng Yu; Jianzhuang Ren; Xinwei Han; Gang Wu
Journal:  Radiol Med       Date:  2018-10-24       Impact factor: 3.469

10.  Stents are associated with increased risk of respiratory infections in patients undergoing airway interventions for malignant airways disease.

Authors:  Horiana B Grosu; George A Eapen; Rodolfo C Morice; Carlos A Jimenez; Roberto F Casal; Francisco A Almeida; Mona G Sarkiss; David E Ost
Journal:  Chest       Date:  2013-08       Impact factor: 9.410

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.