Literature DB >> 17383247

Covalent attachment of proteins to functionalized polypyrrole-coated metallic surfaces for improved biocompatibility.

Wahid Khan1, Mamta Kapoor, Neeraj Kumar.   

Abstract

Stainless steel has been widely used as an implant material for various biomedical applications, but its biocompatibility is still a major issue. Though polymer coating is one of the solutions, biomolecule-attached polymer coating is a better alternative. In this paper, we have synthesized a biomolecule (bovine serum albumin, BSA)-derivatized polymer coating on a stainless steel (316L) surface and evaluated it for biocompatibility. The monomer used for coating was obtained by hydrolyzing 1-(2-cyanoethyl) pyrrole to 1-(2-carboxyethyl) pyrrole followed by activation with N-hydroxysuccinimide to N-succinimidyl ester pyrrole. This monomer was electrocoated onto steel plate to provide a smooth and adherent coating of polypyrrole-N-succinimidyl ester (PPyNSE) which was characterized in terms of surface morphology and chemical composition by scanning electron microscopy and infrared spectroscopy, respectively. Further, BSA was covalently attached to PPyNSE to obtain a biomolecule-derivatized polymer coating. This coating was evaluated for biocompatibility in terms of thrombus formation, platelet adhesion and hemolysis, and was found to be more biocompatible on these parameters than the bare metal and polypyrrole-coated surfaces. Stability studies on these coated plates were also performed.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17383247     DOI: 10.1016/j.actbio.2007.01.006

Source DB:  PubMed          Journal:  Acta Biomater        ISSN: 1742-7061            Impact factor:   8.947


  7 in total

1.  Biocorrosion properties and blood and cell compatibility of pure iron as a biodegradable biomaterial.

Authors:  Erlin Zhang; Haiyan Chen; Feng Shen
Journal:  J Mater Sci Mater Med       Date:  2010-04-16       Impact factor: 3.896

2.  Attenuation of the in vitro neurotoxicity of 316L SS by graphene oxide surface coating.

Authors:  Nishat Tasnim; Alok Kumar; Binata Joddar
Journal:  Mater Sci Eng C Mater Biol Appl       Date:  2017-01-07       Impact factor: 7.328

3.  Biomedical Applications of Biodegradable Polymers.

Authors:  Bret D Ulery; Lakshmi S Nair; Cato T Laurencin
Journal:  J Polym Sci B Polym Phys       Date:  2011-06-15

4.  Optimization of ultraviolet ozone treatment process for improvement of polycaprolactone (PCL) microcarrier performance.

Authors:  Nurhusna Samsudin; Yumi Zuhanis Has-Yun Hashim; Mohd Azmir Arifin; Maizirwan Mel; Hamzah Mohd Salleh; Iis Sopyan; Dzun Noraini Jimat
Journal:  Cytotechnology       Date:  2017-03-23       Impact factor: 2.058

5.  P2000 - A high-nitrogen austenitic steel for application in bone surgery.

Authors:  Mustafa Becerikli; Henriette Jaurich; Christoph Wallner; Johannes Maximilian Wagner; Mehran Dadras; Birger Jettkant; Fabian Pöhl; Merlin Seifert; Ole Jung; Bojan Mitevski; Ahmet Karkar; Marcus Lehnhardt; Alfons Fischer; Max Daniel Kauther; Björn Behr
Journal:  PLoS One       Date:  2019-03-26       Impact factor: 3.240

6.  Effective gamma-ray sterilization and characterization of conductive polypyrrole biomaterials.

Authors:  Semin Kim; Jin-Oh Jeong; Sanghun Lee; Jong-Seok Park; Hui-Jeong Gwon; Sung In Jeong; John George Hardy; Youn-Mook Lim; Jae Young Lee
Journal:  Sci Rep       Date:  2018-02-27       Impact factor: 4.379

7.  Effect of acid-alkali treatment on serum protein adsorption and bacterial adhesion to porous titanium.

Authors:  Juan Zhong; Xuelian Li; Yitong Yao; Jing Zhou; Shanshan Cao; Xinping Zhang; Yutao Jian; Ke Zhao
Journal:  J Mater Sci Mater Med       Date:  2022-02-02       Impact factor: 3.896

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.