Literature DB >> 17381655

Pulmonary venous flow assessed by Doppler echocardiography in the management of atrial fibrillation.

Andreas Bollmann1.   

Abstract

Pulmonary venous blood flow (PVF) visualized by Doppler echocardiography exhibits a pulsatile behavior, which is related to left atrial pressure and function, mitral valve function, and left ventricular compliance. In atrial fibrillation (AF), the disappearance of atrial reverse flow, a decrease in systolic flow with a greater diastolic than systolic flow, a prolonged onset of systolic flow and the appearance of an early systolic reverse flow are characteristic findings. A reduction in systolic PVF expressed by reduced peak velocity, reduced velocity-time integral of systolic flow, and reduced systolic fraction of PVF has been found to be associated with reduced left atrial appendage flow, left atrial spontaneous echo contrast formation, frequency of AF paroxysms and propensity for AF recurrence following restoration of sinus rhythm. Ablation techniques targeting pulmonary vein ostia and adjacent left atrium are promising treatment options to cure AF. Monitoring the PVF response to and adjusting of ablation procedures has been suggested to optimize outcome and prevent complications such as pulmonary vein stenosis. In conclusion, assessment of PVF variables and patterns by Doppler echocardiography seems useful in the management of AF patients. Especially the reduction in systolic PVF may be used as marker for left atrial dysfunction which favors thrombus formation and AF reinitiation. Finally, PVF monitoring has the potential to an increasing role in AF ablation procedures.

Entities:  

Mesh:

Year:  2007        PMID: 17381655     DOI: 10.1111/j.1540-8175.2006.00411.x

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  4 in total

1.  Characterization of the dynamic function of the pulmonary veins before and after atrial fibrillation ablation using multi-detector computed tomographic images.

Authors:  Hsuan-Ming Tsao; Wei-Chih Hu; Mei-Han Wu; Ching-Tai Tai; Shih-Lin Chang; Yenn-Jiang Lin; Li-Wei Lo; Yu-Feng Hu; Tsu-Juey Wu; Ming-Huei Sheu; Cheng-Yen Chang; Shih-Ann Chen
Journal:  Int J Cardiovasc Imaging       Date:  2010-11-26       Impact factor: 2.357

2.  Cryoballoon ablation during atrial fibrillation is associated with faster temperature drop and lower freezing temperatures.

Authors:  Giacomo Mugnai; Darragh Moran; Erwin Ströker; Diego Ruggiero; Hugo Enrique Coutino-Moreno; Ken Takarada; Valentina De Regibus; Rajin Choudhury; Saverio Iacopino; Pasquale Filannino; Vincent Umbrain; Stefan Beckers; Pedro Brugada; Carlo de Asmundis; Gian-Battista Chierchia
Journal:  J Interv Card Electrophysiol       Date:  2016-08-15       Impact factor: 1.900

3.  Correlation between N-Terminal Pro-Brain Natriuretic Peptide and Doppler Echocardiographic Parameters of Left Ventricular Filling Pressure in Atrial Fibrillation.

Authors:  Woo Shin Kim; Seong-Hoon Park
Journal:  J Cardiovasc Ultrasound       Date:  2011-03-31

4.  In vivo bioimaging as a novel strategy to detect doxorubicin-induced damage to gonadal blood vessels.

Authors:  Hadas Bar-Joseph; Irit Ben-Aharon; Moran Tzabari; Galia Tsarfaty; Salomon M Stemmer; Ruth Shalgi
Journal:  PLoS One       Date:  2011-09-09       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.