Literature DB >> 17379570

No sutures corneal grafting--a novel use of overlay sutures and fibrin glue in Deep Anterior Lamellar Keratoplasty.

Niro Narendran1, Shabbir Mohamed, Sunil Shah.   

Abstract

PURPOSE: To describe a case where Deep Anterior Lamellar Keratoplasty (DLK) was performed using overlay sutures and fibrin glue alone, without the need to directly suture the corneal button.
METHODS: Deep Anterior Lamellar Keratoplasty was performed using a modified Melles technique on a 21-year-old patient who had stromal scarring secondary to severe infective keratitis. Overlay sutures and fibrin glue were used to secure the donor button and then a bandage contact lens was inserted. No sutures were required to directly suture the donor button to host tissue. All securing sutures were removed 4 weeks after the surgery. Six months post surgery, the graft was clear and the patient rehabilitated by wearing acceptable astigmatic spectacle correction.
RESULTS: The patients visual acuity in the affected eye was 6/12 wearing a spectacle prescription of -0.25/-3.25x160.
CONCLUSION: The use of overlay sutures and fibrin glue in DLK is a time efficient and effective technique. We propose that this technique may be used routinely in cases where donor corneal button appears to fit well in the stromal bed at the time of surgery, that is, where there is no disparity in the thickness of the donor button compared to the host bed.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17379570     DOI: 10.1016/j.clae.2007.02.007

Source DB:  PubMed          Journal:  Cont Lens Anterior Eye        ISSN: 1367-0484            Impact factor:   3.077


  3 in total

1.  Use of Fibrin Glue in the Management of Descemet Membrane Perforation during Deep Anterior Lamellar Keratoplasty.

Authors:  Saad S Alharbi; Ahmad Alameer
Journal:  Middle East Afr J Ophthalmol       Date:  2019-09-30

2.  Can we overcome the challenges of sutures in lamellar keratoplasty?

Authors:  Anita Panda; Sandeep Kumar
Journal:  Indian J Ophthalmol       Date:  2011 Jul-Aug       Impact factor: 1.848

Review 3.  Fibrin glue in ophthalmology.

Authors:  Anita Panda; Sandeep Kumar; Abhiyan Kumar; Raseena Bansal; Shibal Bhartiya
Journal:  Indian J Ophthalmol       Date:  2009 Sep-Oct       Impact factor: 1.848

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.