AIMS: Computed tomography planning of whole breast radiotherapy (WBRT) improves breast coverage and reduces the normal tissue dose. Computed tomography planning may increase tumour bed boost treatment accuracy. The aims of this investigation were (1) to compare the breast boost volume treated with clinical mark-up with the volume delineated with computed tomography planning and (2) to study tumour bed volume changes between the initial planning computed tomography scan and a second computed tomography scan at the time of breast boost mark-up.
MATERIALS AND METHODS: Women receiving adjuvant WBRT and an electron boost after breast-conserving surgery were eligible. As per standard practice, WBRT was computed tomography planned while the boost electron portal was clinically defined. Electron field borders were then traced with wire and a second computed tomography scan was carried out in the boost treatment position. Post-surgical radiological abnormalities were contoured to create a tumour bed clinical target volume (CTV) on both scans (CTV1 and CTV2). A 1cm margin to CTV2 defined the planning target volume (PTV). The proportions of the CTV2 and PTV receiving 90% (V90) and 80% (V80) of the dose were calculated. Changes in volume between CTV1 and CTV2 were analysed.
RESULTS: Data from 47 eligible patients were analysed. The mean V90 for the PTV was 61%. Lower electron energy (P<0.001) and small field sizes (P=0.004) were associated with a low V90. The mean CTV decreased by 4.3 cm3 (P=0.014) and was smaller in those with a long surgery to computed tomography interval (P=0.008). On average, the 90% isodose covered 61 cm3 of normal tissue.
CONCLUSIONS: Conventional clinical breast boost planning is inaccurate. Electron boost computed tomography planning together with appropriate surgical clip placement and the use of mammograms and pathological information should provide optimal coverage of the tumour site. The boost could usually be planned from the initial computed tomography scan.

Entities:  

Mesh:

Year:  2007        PMID: 17379487     DOI: 10.1016/j.clon.2007.02.002

Source DB:  PubMed          Journal:  Clin Oncol (R Coll Radiol)        ISSN: 0936-6555            Impact factor:   4.126


  2 in total

1.  3-D conformal photon boost in the treatment of early stage breast cancer: four year follow up results.

Authors:  Arpad Kovacs; Ferenc Lakosi; Gabor Liposits; Gabor Toller; Janaki Hadjiev; Csaba Vandulek; Norbert Walter; Csaba Glavak; Gergely Antal; Akos Horvath; Imre Repa; Peter Bogner
Journal:  Pathol Oncol Res       Date:  2010-04-11       Impact factor: 3.201

2.  Magnetic Resonance Imaging for Breast Tumor Bed Delineation: Computed Tomography Comparison and Sequence Variation.

Authors:  Nicola Lowrey; Christine A Koch; Thomas Purdie; Anna Simeonov; Leigh Conroy; Kathy Han
Journal:  Adv Radiat Oncol       Date:  2021-05-26
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.