Literature DB >> 17378738

Multicentre physiological reference intervals for serum concentrations of immunoglobulins A, G and M, complement C3c and C4 measured with Tina-Quant reagents systems.

Xavier Fuentes-Arderiu1, Eduardo Alonso-Gregorio, Virtudes Alvarez-Funes, Carmen Ambrós-Marigómez, Lluís Coca-Fábregas, Marta Cruz-Placer, Julián Díaz-Fernández, María Pilar Pinel-Julián, Beatriz Gutiérrez-Cecchini, Pilar Herrero-Bernal, Marcos Sempere-Alcocer, Francisca García-Caballero, María Del Mar Larrea-Ortiz-Quintana, Pedro La-Torre-Marcellán, María Del Señor López-Vélez, Carmen Mar-Medina, Javier Martín-Oncina, María Victoria Rodríguez-Hernández, María Victoria Romero-Sotomayor, Cándido Serrano-López, Adolfo Sicilia-Enríquez-de-Salamanca, Ana María Velasco-Romero, Santiago Juvé-Cuxart.   

Abstract

BACKGROUND: Clinical laboratories seeking accreditation for compliance with ISO 15189:2003 need to demonstrate that the physiological reference intervals communicated to all users of the laboratory service are appropriate for the patient population served and for the measurement systems used. In the case of immunological quantities, few articles have been published in peer-reviewed journals.
METHODS: A total of 21 clinical laboratories in different regions of Spain collaborated in identifying reference individuals and determining adult reference intervals for some immunological quantities measured using RD/Hitachi Modular Analytics analysers and Tina-Quant reagent systems. These immunological quantities are the mass concentrations of immunoglobulin A, immunoglobulin G, immunoglobulin M, complement C3c and complement C4 in serum. All the logistic work was carried out in co-operation with the supplier of the reagents and analysers (Roche Diagnostics España, S.L., Sant Cugat del Vallès, Catalonia, Spain). From the set of reference values obtained by each laboratory, multicentre reference limits were estimated non-parametrically. RESULTS AND
CONCLUSIONS: The reference intervals estimated in this study for concentrations of serum components under consideration are: complement C3c, 0.62-1.64 g/L for women and men; complement C4, 0.14-0.72 g/L for women and men; immunoglobulin A, 0.89-4.80 g/L for women and men; immunoglobulin G, 6.5-14.3 g/L for women and men; and immunoglobulin M, 0.48-3.38 g/L for women and 0.41-2.46 g/L for men.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17378738     DOI: 10.1515/CCLM.2007.069

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  1 in total

1.  Reference Intervals for Serum Immunoglobulins IgG, IgA, IgM and Complements C3 and C4 in Iranian Healthy Children.

Authors:  Ga Kardar; M Oraei; M Shahsavani; Z Namdar; Ge Kazemisefat; Mt Haghi Ashtiani; S Shams; Z Pourpak; M Moin
Journal:  Iran J Public Health       Date:  2012-07-31       Impact factor: 1.429

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.