Literature DB >> 17377051

MR arthrography of the shoulder, hip, and wrist: evaluation of contrast dynamics and image quality with increasing injection-to-imaging time.

Gustav Andreisek1, Sylvain R Duc, Johannes M Froehlich, Juerg Hodler, Dominik Weishaupt.   

Abstract

OBJECTIVE: The purpose of our study was to investigate the contrast dynamics and the relationship between visualization of intraarticular structures and time elapsed between intraarticular injection of contrast agent and MRI in symptomatic patients referred for MR arthrography of the shoulder, hip, and wrist. SUBJECTS AND METHODS: Our local ethics committees and the national drug administration approved this multicentric study. We prospectively studied 11 shoulders, 11 hips, and 10 wrists. After the intraarticular gadolinium injection, patients underwent a baseline MR arthrography protocol (time point [TP] 1) and subsequent MRI at another four time points (TP 2-TP 5) up to 240 minutes. The course of contrast-to-noise ratio (CNR) over time was calculated. Three observers assessed the degree of visualization of different intraarticular structures and the overall image quality at each time point using a 3-point scale and a 5-point scale, respectively.
RESULTS: For all joints, CNR measurements showed peak CNR at TP 1 (21 minutes) and TP 2 (45 minutes) with a subsequent, near-logarithmic decline of CNR values over time. Visualization of different anatomic structures decreased over time. Overall image quality was insufficient for diagnostic purposes at TP 3 (96 minutes) in three (27%) of 11 shoulders and in three (27%) of 11 hips. In two (20%) of 10 wrists, image quality was insufficient at TP 2 (45 minutes).
CONCLUSION: For MR arthrography, the degree of visualization of intraarticular structures depends on the time elapsed between contrast injection and MRI. MR arthrography of the shoulder and hip should be performed within 90 minutes, and MR arthrography of the wrist should be performed within 45 minutes, after intraarticular injection.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17377051     DOI: 10.2214/AJR.06.0719

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  12 in total

Review 1.  The biological fate of gadolinium-based MRI contrast agents: a call to action for bioinorganic chemists.

Authors:  Mariane Le Fur; Peter Caravan
Journal:  Metallomics       Date:  2019-02-20       Impact factor: 4.526

2.  Ultrasound guidance to perform intra-articular injection of gadolinium-based contrast material for magnetic resonance arthrography as an alternative to fluoroscopy: the time is now.

Authors:  Carmelo Messina; Giuseppe Banfi; Alberto Aliprandi; Giovanni Mauri; Francesco Secchi; Francesco Sardanelli; Luca Maria Sconfienza
Journal:  Eur Radiol       Date:  2015-08-08       Impact factor: 5.315

3.  T2* relaxation time of acetabular and femoral cartilage with and without intraarticular gadopentetate dimeglumine in patients with femoroacetabular impingement.

Authors:  Mikko J Nissi; Shabnam Mortazavi; John Hughes; Patrick Morgan; Jutta Ellermann
Journal:  AJR Am J Roentgenol       Date:  2015-06       Impact factor: 3.959

4.  Freehand direct arthrography of the shoulder using near real-time guidance in an open 1.0-T MRI scanner.

Authors:  Christian Wybranski; Ilya Adamchic; Friedrich-Wilhelm Röhl; Jens Ricke; Frank Fischbach; Katharina Fischbach
Journal:  Skeletal Radiol       Date:  2016-10-22       Impact factor: 2.199

Review 5.  MRI of weight bearing and movement.

Authors:  L M Shapiro; G E Gold
Journal:  Osteoarthritis Cartilage       Date:  2011-11-17       Impact factor: 6.576

6.  Diagnostic performance of CT-arthrography and 1.5T MR-arthrography for the assessment of glenohumeral joint cartilage: a comparative study with arthroscopic correlation.

Authors:  Patrick Omoumi; Alexandra Rubini; Jean-Emile Dubuc; Bruno C Vande Berg; Frédéric E Lecouvet
Journal:  Eur Radiol       Date:  2014-11-08       Impact factor: 5.315

7.  Comparison of MR-arthrography and MDCT-arthrography for detection of labral and articular cartilage hip pathology.

Authors:  Evangelos Perdikakis; Theofilos Karachalios; Pavlos Katonis; Apostolos Karantanas
Journal:  Skeletal Radiol       Date:  2011-02-06       Impact factor: 2.199

8.  A Manganese-based Alternative to Gadolinium: Contrast-enhanced MR Angiography, Excretion, Pharmacokinetics, and Metabolism.

Authors:  Eric M Gale; Hsiao-Ying Wey; Ian Ramsay; Yi-Fen Yen; David E Sosnovik; Peter Caravan
Journal:  Radiology       Date:  2017-11-08       Impact factor: 11.105

9.  Manganese-Based Contrast Agents for Magnetic Resonance Imaging of Liver Tumors: Structure-Activity Relationships and Lead Candidate Evaluation.

Authors:  Junfeng Wang; Huan Wang; Ian A Ramsay; Derek J Erstad; Bryan C Fuchs; Kenneth K Tanabe; Peter Caravan; Eric M Gale
Journal:  J Med Chem       Date:  2018-09-25       Impact factor: 7.446

10.  Gadolinium retention within multiple rat organs after intra-articular administration of gadolinium-based contrast agents.

Authors:  Michael D Ringler; Nicholas G Rhodes; Jennifer R Ayers-Ringler; Daniel R Jakaitis; Robert J McDonald; David F Kallmes; Jennifer S McDonald
Journal:  Skeletal Radiol       Date:  2021-01-06       Impact factor: 2.199

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.