Literature DB >> 1737542

Randomized comparison of metabolic control achieved by intraperitoneal insulin infusion with implantable pumps versus intensive subcutaneous insulin therapy in type I diabetic patients.

J L Selam1, D Raccah, N Jean-Didier, J L Lozano, K Waxman, M A Charles.   

Abstract

OBJECTIVE: To compare intraperitoneal implantable insulin infusion (IP) to subcutaneous (SC) intensive insulin therapy. RESEARCH DESIGN AND METHODS: Twenty-one insulin-dependent (type I) diabetic patients aged 24-61 yr underwent a 3-mo treatment optimization using multiple SC daily injections or external pumps. Patients were then randomized (time 0 mo) to IP infusion using Infusaid-programmable pumps or continuation on SC intensive insulin for 6 mo.
RESULTS: No differences were noted between study and control group data. However, longitudinal within-group comparisons from baseline showed that glycosylated hemoglobin improved to near-normal in both groups: IP, 9.0 +/- 0.5 vs. 7.8 +/- 0.6% (P less than 0.05) and SC, 8.4 +/- 0.5 vs. 7.5 +/- 0.3% (P less than 0.5) at 0 and 4 mo, respectively (normal less than 6.9%). The percentage of blood glucose tests greater than 11 mM at 0 and 6 mo was 28 +/- 5 vs. 16 +/- 4% in the IP group (P less than 0.05) and 22 +/- 5 vs. 24 +/- 7% in the SC group (NS). At 0 and 6 mo, the standard deviation of blood glucose values, an index of glycemic fluctuations, was 4.3 +/- 0.4 vs. 3.2 +/- 0.5 mM in the IP group (P less than 0.05) and 3.7 +/- 0.3 vs. 4.0 +/- 0.4 mM in the SC group (NS). Weight, insulin dosages, circulating lipid levels, and the frequency of severe hypoglycemic reactions and biochemical hypoglycemias were similar and did not change in the two groups.
CONCLUSIONS: IP-implantable pumps compared with SC intensive insulin therapy have similar effects on most metabolic variables and are equally effective at achieving near-normal glycemic levels. Only longitudinal data suggest that IP treatment may be more effective at limiting glycemic fluctuations.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1737542     DOI: 10.2337/diacare.15.1.53

Source DB:  PubMed          Journal:  Diabetes Care        ISSN: 0149-5992            Impact factor:   19.112


  10 in total

1.  Targeting insulin to the liver corrects defects in glucose metabolism caused by peripheral insulin delivery.

Authors:  Dale S Edgerton; Melanie Scott; Ben Farmer; Phillip E Williams; Peter Madsen; Thomas Kjeldsen; Christian L Brand; Christian Fledelius; Erica Nishimura; Alan D Cherrington
Journal:  JCI Insight       Date:  2019-02-26

2.  A New Optimized Percutaneous Access System for CIPII.

Authors:  Rosa Garcia-Verdugo; Michael Erbach; Oliver Schnell
Journal:  J Diabetes Sci Technol       Date:  2017-03-01

Review 3.  Finding the right route for insulin delivery - an overview of implantable pump therapy.

Authors:  Lia Bally; Hood Thabit; Roman Hovorka
Journal:  Expert Opin Drug Deliv       Date:  2016-12-07       Impact factor: 6.648

4.  Improved glycemic control with intraperitoneal versus subcutaneous insulin in type 1 diabetes: a randomized controlled trial.

Authors:  Susan J Logtenberg; Nanne Kleefstra; Sebastiaan T Houweling; Klaas H Groenier; Reinold O Gans; Evert van Ballegooie; Henk J Bilo
Journal:  Diabetes Care       Date:  2009-05-08       Impact factor: 17.152

5.  Surgical aspects and complications of continuous intraperitoneal insulin infusion with an implantable pump.

Authors:  Jan Willem Haveman; Susan J J Logtenberg; Nanne Kleefstra; Klaas H Groenier; Henk J G Bilo; Adri M Blomme
Journal:  Langenbecks Arch Surg       Date:  2008-12-02       Impact factor: 3.445

Review 6.  Implantable insulin pumps and metabolic control.

Authors:  K D Hepp
Journal:  Diabetologia       Date:  1994-09       Impact factor: 10.122

7.  Immunogenicity of intraperitoneal insulin infusion using programmable implantable devices.

Authors:  N Jeandidier; S Boivin; R Sapin; F Rosart-Ortega; B Uring-Lambert; P Réville; M Pinget
Journal:  Diabetologia       Date:  1995-05       Impact factor: 10.122

8.  Continuous intraperitoneal insulin infusion in type 1 diabetes: a 6-year post-trial follow-up.

Authors:  Peter R van Dijk; Susan J J Logtenberg; Klaas H Groenier; Rijk O B Gans; Nanne Kleefstra; Henk Jg Bilo
Journal:  BMC Endocr Disord       Date:  2014-04-07       Impact factor: 2.763

9.  Different routes of insulin administration do not influence serum free thiols in type 1 diabetes mellitus.

Authors:  Peter R van Dijk; Femke Waanders; Susan J J Logtenberg; Klaas H Groenier; Titia M Vriesendorp; Nanne Kleefstra; Harry van Goor; Henk J G Bilo
Journal:  Endocrinol Diabetes Metab       Date:  2019-08-08

10.  Changes in glucose and fat metabolism in response to the administration of a hepato-preferential insulin analog.

Authors:  Dale S Edgerton; Mary C Moore; Jason J Winnick; Melanie Scott; Ben Farmer; Helle Naver; Claus B Jeppesen; Peter Madsen; Thomas B Kjeldsen; Erica Nishimura; Christian L Brand; Alan D Cherrington
Journal:  Diabetes       Date:  2014-06-19       Impact factor: 9.461

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.