Literature DB >> 17372368

Integration of a nanoporous platinum thin film into a microfluidic system for non-enzymatic electrochemical glucose sensing.

Segyeong Joo1, Sejin Park, Taek Dong Chung, Hee Chan Kim.   

Abstract

In this paper, we describe an amperometric-type enzymeless glucose sensing system based on a nanoporous platinum (Pt) electrode embedded in a microfluidic chip. This microchip system is comprised of a microfluidic transport channel network and a miniaturized electrochemical cell for nonenzymatic glucose sensing. Sample and buffer solutions were transferred to the cell by programmed electroosmotic flow (EOF). A nanoporous Pt electrode with the roughness factor of 200.6 was utilized to determine glucose concentrations in phosphate buffered saline (PBS) by the direct oxidation of glucose, without any separation process. The sensitivity of the developed system is 1.65 microA cm-2 mM-1 in the glucose concentration range from 1-10 mM in PBS.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17372368     DOI: 10.2116/analsci.23.277

Source DB:  PubMed          Journal:  Anal Sci        ISSN: 0910-6340            Impact factor:   2.081


  5 in total

1.  Interplay of Effective Surface Area, Mass Transport, and Electrochemical Features in Nanoporous Nucleic Acid Sensors.

Authors:  Jovana Veselinovic; Suzan AlMashtoub; Sachit Nagella; Erkin Seker
Journal:  Anal Chem       Date:  2020-07-14       Impact factor: 6.986

Review 2.  Nanoporous membranes for medical and biological applications.

Authors:  Shashishekar P Adiga; Chunmin Jin; Larry A Curtiss; Nancy A Monteiro-Riviere; Roger J Narayan
Journal:  Wiley Interdiscip Rev Nanomed Nanobiotechnol       Date:  2009 Sep-Oct

3.  Electrically Guided DNA Immobilization and Multiplexed DNA Detection with Nanoporous Gold Electrodes.

Authors:  Jovana Veselinovic; Zidong Li; Pallavi Daggumati; Erkin Seker
Journal:  Nanomaterials (Basel)       Date:  2018-05-21       Impact factor: 5.076

4.  Fabrication of 2D-MoSe2 incorporated NiO Nanorods modified electrode for selective detection of glucose in serum samples.

Authors:  Gayathri Jeevanandham; Kumaran Vediappan; Zeid A ALOthman; Tariq Altalhi; Ashok K Sundramoorthy
Journal:  Sci Rep       Date:  2021-06-24       Impact factor: 4.379

5.  Fabrication of a microneedle/CNT hierarchical micro/nano surface electrochemical sensor and its in-vitro glucose sensing characterization.

Authors:  Youngsam Yoon; Gil S Lee; Koangki Yoo; Jeong-Bong Lee
Journal:  Sensors (Basel)       Date:  2013-12-04       Impact factor: 3.576

  5 in total