MR volumetric measurements of the myomatous uterus: improved reliability of stereology over linear measurements.

Bonnie N Joe1, Jongdae Suh, Charles F Hildebolt, David M Hovsepian, Brian Johnston, Kyongtae T Bae.   

Abstract

RATIONALE AND
OBJECTIVES: Stereology is a simple, fast method for object segmentation that involves counting the number of intersections of a randomly positioned grid over an object. The objectives of this study were to determine observer reliability in making stereologic- and ellipsoid-based measurements of uterine and leiomyoma volumes and to test the agreement between these two methods of measurement.
MATERIALS AND METHODS: Two observers made uterine and dominant leiomyoma volume measurements on MR images in 30 patients using stereology and the popular ellipsoid-based technique. Stereologic volume measurements were made from high-resolution T2 images in two perpendicular planes (axial and sagittal). Ellipsoid volume was calculated by multiplying the maximal sagittal, anteroposterior, and transverse dimensions by pi/6. For these measurements, interobserver reliability was tested with paired t-tests and percent differences were determined. A mean stereologic volume and a mean ellipsoid volume were determined and tested for agreement with a paired t-test. Percent differences were also calculated.
RESULTS: Stereologic measurements demonstrated excellent interobserver reliability with 0.3% difference in mean uterine volumes (P = .69) and 0.3% difference (P = .81) in mean leiomyoma volumes. The ellipsoid method resulted in poorer interobserver reliability with 7% difference (P = .01) in mean uterine volumes and 4% difference (p = .24) in mean leiomyoma volumes. The ellipsoid method also significantly overestimated uterine volumes by 14% (P < .01) compared with stereology.
CONCLUSION: Stereology provided high interobserver reliability for leiomyoma and overall uterine volume measurements and was more reliable than the ellipsoid method, which uses linear measurements. Stereology appears well suited when precise volume measurements are desired for assessing response to uterine arterial embolization treatments.

Entities:  

Mesh:

Year:  2007        PMID: 17368215     DOI: 10.1016/j.acra.2007.01.004

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  3 in total

1.  Application of stereological estimates in patients with severe head injuries using CT and MR scanning images.

Authors:  N Eriksen; E Rostrup; K Andersen; M J Lauritzen; M Fabricius; V A Larsen; J P Dreier; A J Strong; J A Hartings; B Pakkenberg
Journal:  Br J Radiol       Date:  2009-08-18       Impact factor: 3.039

2.  Clinical application of SPHARM-PDM to quantify temporomandibular joint osteoarthritis.

Authors:  Beatriz Paniagua; Lucia Cevidanes; David Walker; Hongtu Zhu; Ruixin Guo; Martin Styner
Journal:  Comput Med Imaging Graph       Date:  2010-12-24       Impact factor: 4.790

3.  Unbiased and efficient estimation of the volume of the fibroid uterus using the Cavalieri method and magnetic resonance imaging.

Authors:  Michael J Thrippleton; Kirsty I Munro; Graham McKillop; David E Newby; Ian Marshall; Neil Roberts; Hilary O D Critchley
Journal:  Reprod Sci       Date:  2014-10-20       Impact factor: 3.060