Literature DB >> 17367170

Incorporation of glucose oxidase into Langmuir-Blodgett films based on Prussian blue applied to amperometric glucose biosensor.

Hitoshi Ohnuki1, Takafumi Saiki, Akira Kusakari, Hideaki Endo, Masaki Ichihara, Mitsuru Izumi.   

Abstract

Glucose oxidase (GOx) was immobilized in the organic-inorganic Langmuir-Bldogett (LB) films consisting of octadecyltrimethylammonium (ODTA) and nanosized Prussian blue (PB) clusters. The amperometric glucose biosensors based on the LB films were fabricated and tested. It was found that the sensors exhibited a clear response current under an applied voltage of 0.0 V (vs Ag/AgCl). The linearity of current density versus glucose concentration was confirmed below 15 mmol/L concentration. This is the first observation of biosensor function of the hybrid organic-inorganic LB films. The successful preparation of glucose sensors operating at the very low potential indicates that the adsorbed PB clusters in the LB films act as an electrocatalyst for the electrochemical reduction of hydrogen peroxide, which is the final product of the enzymatic reaction sequence. The observed low potential applicability is estimated to inhibit the responses of interferants such as ascorbic acid, uric acid, and acetominophen. It was also found that an electrostatic interaction between positively charged ODTA+ and the adsorbed species of both GOx and PB provided a stabilized adsorption state in the LB films. Such stable immobilization contributes to the steady amperometric response current observed in the present ODTA/PB/GOx LB films.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17367170     DOI: 10.1021/la063175g

Source DB:  PubMed          Journal:  Langmuir        ISSN: 0743-7463            Impact factor:   3.882


  4 in total

Review 1.  Nanozymes in Point-of-Care Diagnosis: An Emerging Futuristic Approach for Biosensing.

Authors:  Bhaskar Das; Javier Lou Franco; Natasha Logan; Paramasivan Balasubramanian; Moon Il Kim; Cuong Cao
Journal:  Nanomicro Lett       Date:  2021-09-13

Review 2.  Electrochemical Sensors for Clinic Analysis.

Authors:  You Wang; Hui Xu; Jianming Zhang; Guang Li
Journal:  Sensors (Basel)       Date:  2008-03-27       Impact factor: 3.576

Review 3.  Fully integrated biochip platforms for advanced healthcare.

Authors:  Sandro Carrara; Sara Ghoreishizadeh; Jacopo Olivo; Irene Taurino; Camilla Baj-Rossi; Andrea Cavallini; Maaike Op de Beeck; Catherine Dehollain; Wayne Burleson; Francis Gabriel Moussy; Anthony Guiseppi-Elie; Giovanni De Micheli
Journal:  Sensors (Basel)       Date:  2012-08-08       Impact factor: 3.576

4.  A Novel Biomimetic Tool for Assessing Vitamin K Status Based on Molecularly Imprinted Polymers.

Authors:  Kasper Eersels; Hanne Diliën; Joseph W Lowdon; Erik Steen Redeker; Renato Rogosic; Benjamin Heidt; Marloes Peeters; Peter Cornelis; Petra Lux; Chris P Reutelingsperger; Leon J Schurgers; Thomas J Cleij; Bart van Grinsven
Journal:  Nutrients       Date:  2018-06-11       Impact factor: 5.717

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.