Literature DB >> 17365998

Carbohydrate-deficient transferrin determined in blood microsamples from healthy newborns by using capillary zone electrophoresis.

G Zamboni1, F Bortolotti, M Zaffanello, G De Paoli, F Tagliaro.   

Abstract

OBJECTIVE: There is a paucity of studies on quantitative determination of carbohydrate-deficient transferrin (CDT) in newborns. The aim of our study was therefore to determine CDT concentrations in newborns by using capillary zone electrophoresis (CZE).
MATERIAL AND METHODS: Capillary blood was collected from the heels of 28 at-term healthy newborns, simultaneously with the Guthrie card screening. Forty-seven adults were examined as controls. CZE separations were performed with a P/ACE MDQ capillary electropherograph in uncoated fused-silica capillaries using a commercial reagent kit. After iron saturation, the samples were loaded by application of 0.5 psi for 15 s, and separated under 28kV with UV detection. All relevant transferrin (Tf) glycoforms were separated within 7 min. CDT quantification (%CDT) was carried out by calculating the percentage ratio between the sum of the peak areas of CDT-related glycoforms and the sum of peak areas of all Tf glycoforms.
RESULTS: In most cases, good separations of Tf glycoforms were obtained. In the newborns the %CDT was 0.51 versus 0.66 in adults (difference not statistically significant). Trisialo-Tf concentration was significantly lower in newborns (3.20) than in adults (4.11). Furthermore, pentasialo-Tf appeared to be lower in newborns (7.30) than in adults (14.00), but because complete separation of the peaks of tetrasialo- and pentasialo-Tf was not always possible, this finding could not be confirmed statistically.
CONCLUSIONS: CZE showed definite advantages in terms of volume of blood to be collected, simplicity and standardization of analysis and, because of the direct detection of the separated zones, accuracy of quantification. The present study provides the basic information in the search for glycosylation defects in newborns.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17365998     DOI: 10.1080/00365510601004077

Source DB:  PubMed          Journal:  Scand J Clin Lab Invest        ISSN: 0036-5513            Impact factor:   1.713


  1 in total

1.  Fast screening of N-glycosylation disorders by sialotransferrin profiling with capillary zone electrophoresis.

Authors:  H A Kingma; F H van der Sluijs; M R Heiner-Fokkema
Journal:  Ann Clin Biochem       Date:  2018-06-11       Impact factor: 2.057

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.