Literature DB >> 17365050

Real-ear measurement verification for open, non-occluding hearing instruments.

Johannes Lantz1, Ole Dyrlund Jensen, Astrid Haastrup, Steen Østergaard Olsen.   

Abstract

Real-ear measurements using the modified pressure method with concurrent (real-time) equalization can be inaccurate, when amplified sound leaks out of the ear canal and reaches the reference microphone. In such situations the reference microphone will detect an increased sound level and reduce the output of the loudspeaker to maintain the desired level. The risk of having errors due to leaks increases if digital feedback suppression (DFS) is used, thus achieving higher feedback-free gain levels. The following hypotheses were tested: a) using the concurrent equalization method for fitting hearing instruments with DFS may result in underestimated real-ear insertion gain (especially when using open fittings) and b) as the benefit of the DFS system increases, this error also increases. Real-ear measurements were carried out in twenty-one subjects using the modified pressure method with stored equalization as well as with concurrent equalization. The results of the study supports both hypotheses. As a consequence it is recommended to use a stored equalization method for real-ear measurements of hearing instruments with DFS and open fitting.

Entities:  

Mesh:

Year:  2007        PMID: 17365050     DOI: 10.1080/14992020601083313

Source DB:  PubMed          Journal:  Int J Audiol        ISSN: 1499-2027            Impact factor:   2.117


  4 in total

1.  A multicenter trial of an assess-and-fit hearing aid service using open canal fittings and comply ear tips.

Authors:  Pauline Smith; Angela Mack; Adrian Davis
Journal:  Trends Amplif       Date:  2008-06

2.  Comparison of the benefits of cochlear implantation versus contra-lateral routing of signal hearing aids in adult patients with single-sided deafness: study protocol for a prospective within-subject longitudinal trial.

Authors:  Pádraig T Kitterick; Gerard M O'Donoghue; Mark Edmondson-Jones; Andrew Marshall; Ellen Jeffs; Louise Craddock; Alison Riley; Kevin Green; Martin O'Driscoll; Dan Jiang; Terry Nunn; Shakeel Saeed; Wanda Aleksy; Bernhard U Seeber
Journal:  BMC Ear Nose Throat Disord       Date:  2014-08-11

Review 3.  Open Versus Closed Hearing-Aid Fittings: A Literature Review of Both Fitting Approaches.

Authors:  Alexandra Winkler; Matthias Latzel; Inga Holube
Journal:  Trends Hear       Date:  2016-02-15       Impact factor: 3.293

4.  Reliability of real ear insertion gain in behind-the-ear hearing aids with different coupling systems to the ear canal.

Authors:  Charlotte Thunberg Jespersen; Kimi Nina Møller
Journal:  Int J Audiol       Date:  2013-01-09       Impact factor: 2.117

  4 in total