Literature DB >> 17362190

Laparoscopic salvage of malfunctioning Tenckhoff catheters.

Alp Numanoglu1, Mignon I McCulloch, Anne Van Der Pool, Alastair J W Millar, Heinz Rode.   

Abstract

PURPOSE: Peritoneal dialysis is a practical and appropriate form of dialysis in developing countries, as patients can be trained to do this at home. The aim of this study was to assess the efficacy of laparoscopic techniques in managing malfunctioning Tenckhoff catheters in a supraregional nephrology and transplant center.
MATERIALS AND METHODS: Between 2001 and 2004, 43 patients required Tenckhoff catheter insertion (20 males and 23 females). The average age was 8.9 years (range, 2-17 years). Four patients had their catheter tip sutured to the pelvic peritoneum and 11 underwent omentectomy at initial insertion. Laparoscopic salvage was performed using two or three 5-mm ports. If required, the tip of the catheter could be inspected and cleaned by delivering it through one of the port sites. The catheter was then replaced in the abdomen with the tip lying in the pelvis. Twenty patients (6 males and 14 females) required surgical correction for malfunctioning catheters. Eleven underwent a total of 13 laparoscopic salvage operations, and 9 patients had open replacement of catheters.
RESULTS: The causes of malfunction identified in the laparoscopic group were occlusion by fimbriae (n = 4) or omentum (n = 1), peritonitis (n = 4), and displacement of catheter (n = 4). In the open replacement group 2 patients had peritonitis, 1 had occlusion due to fimbriae, and 1 due to omentum. Five had no cause identified. Re-look laparotomy and diathermy hemostasis of fimbriae was required in one patient due to bleeding from fimbriae following laparoscopic retraction of fimbriae from the peritoneal dialysis catheter.
CONCLUSION: Twenty of forty-three (46%) patients required Tenckhoff catheter salvage surgery. The laparoscopic approach enabled us to visualize the cause of malfunction and correct problems without reinsertion of a new catheter, as had been our previous practice.

Entities:  

Mesh:

Year:  2007        PMID: 17362190     DOI: 10.1089/lap.2006.0542

Source DB:  PubMed          Journal:  J Laparoendosc Adv Surg Tech A        ISSN: 1092-6429            Impact factor:   1.878


  4 in total

1.  Single-port laparoscopy for salvaging outflow failure from omental wrapping.

Authors:  A Yamada; T Hiraiwa; Y Tsuji; N Ueda
Journal:  Perit Dial Int       Date:  2012 Nov-Dec       Impact factor: 1.756

2.  Guidelines for laparoscopic peritoneal dialysis access surgery.

Authors:  Stephen Haggerty; Scott Roth; Danielle Walsh; Dimitrios Stefanidis; Raymond Price; Robert D Fanelli; Todd Penner; William Richardson
Journal:  Surg Endosc       Date:  2014-10-08       Impact factor: 4.584

3.  Laparoscopic versus open peritoneal dialysis catheter placement.

Authors:  Tiffany C Cox; Laurel J Blair; Ciara R Huntington; Tanushree Prasad; Kent W Kercher; B Todd Heniford; Vedra A Augenstein
Journal:  Surg Endosc       Date:  2015-06-20       Impact factor: 4.584

4.  A novel method for salvage of malfunctioning peritoneal dialysis catheter.

Authors:  Ali Akbar Beig; Sayed Mahdi Marashi; Hojatollah Raji Asadabadi; Ali Sharifi; Zohre Nasiri Zarch
Journal:  Urol Ann       Date:  2014-04
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.