Literature DB >> 17361301

Focus-engineered coherent anti-Stokes Raman scattering microscopy: a numerical investigation.

Vishnu Vardhan Krishnamachari1, Eric Olaf Potma.   

Abstract

The coherent anti-Stokes Raman scattering (CARS) signal is calculated as a function of focal-field distributions with engineered phase jumps. We show that the focal fields in CARS microscopy can be shaped such that the signal from the bulk is suppressed in the forward detection mode. We present the field distributions that display enhanced sensitivity to vibrationally resonant object interfaces in the lateral dimension. The use of focus-engineered CARS provides a simple means to detect chemical edges against the strong background signals from the bulk.

Mesh:

Year:  2007        PMID: 17361301     DOI: 10.1364/josaa.24.001138

Source DB:  PubMed          Journal:  J Opt Soc Am A Opt Image Sci Vis        ISSN: 1084-7529            Impact factor:   2.129


  7 in total

Review 1.  Coherent anti-Stokes Raman scattering microscopy.

Authors:  Ji-Xin Cheng
Journal:  Appl Spectrosc       Date:  2007-09       Impact factor: 2.388

2.  Multiplicative and subtractive focal volume engineering in coherent Raman microscopy.

Authors:  Varun Raghunathan; Eric Olaf Potma
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2010-11-01       Impact factor: 2.129

3.  Effect of scattering on coherent anti-Stokes Raman scattering (CARS) signals.

Authors:  Janaka C Ranasinghesagara; Giuseppe De Vito; Vincenzo Piazza; Eric O Potma; Vasan Venugopalan
Journal:  Opt Express       Date:  2017-04-17       Impact factor: 3.894

4.  Interferometric switching of coherent anti-Stokes Raman scattering signals in microscopy.

Authors:  Alexei Nikolaenko; Vishnu Vardhan Krishnamachari; Eric Olaf Potma
Journal:  Phys Rev A       Date:  2009-01-01       Impact factor: 3.140

Review 5.  Coherent anti-Stokes Raman scattering microscopy: overcoming technical barriers for clinical translation.

Authors:  Haohua Tu; Stephen A Boppart
Journal:  J Biophotonics       Date:  2013-05-14       Impact factor: 3.207

6.  Controlling stimulated coherent spectroscopy and microscopy by a position-dependent phase.

Authors:  Chao-Yu Chung; Julie Hsu; Shaul Mukamel; Eric O Potma
Journal:  Phys Rev A       Date:  2013-03-26       Impact factor: 3.140

7.  Coherent anti-Stokes Raman scattering imaging of microcalcifications associated with breast cancer.

Authors:  Georgi I Petrov; Rajan Arora; Vladoslav V Yakovlev
Journal:  Analyst       Date:  2020-12-17       Impact factor: 4.616

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.