Literature DB >> 17356626

Gaussian approximations of fluorescence microscope point-spread function models.

Bo Zhang1, Josiane Zerubia, Jean-Christophe Olivo-Marin.   

Abstract

We comprehensively study the least-squares Gaussian approximations of the diffraction-limited 2D-3D paraxial-nonparaxial point-spread functions (PSFs) of the wide field fluorescence microscope (WFFM), the laser scanning confocal microscope (LSCM), and the disk scanning confocal microscope (DSCM). The PSFs are expressed using the Debye integral. Under an L(infinity) constraint imposing peak matching, optimal and near-optimal Gaussian parameters are derived for the PSFs. With an L1 constraint imposing energy conservation, an optimal Gaussian parameter is derived for the 2D paraxial WFFM PSF. We found that (1) the 2D approximations are all very accurate; (2) no accurate Gaussian approximation exists for 3D WFFM PSFs; and (3) with typical pinhole sizes, the 3D approximations are accurate for the DSCM and nearly perfect for the LSCM. All the Gaussian parameters derived in this study are in explicit analytical form, allowing their direct use in practical applications.

Entities:  

Mesh:

Year:  2007        PMID: 17356626     DOI: 10.1364/ao.46.001819

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  74 in total

1.  Photoluminescence imaging of electronic-impurity-induced exciton quenching in single-walled carbon nanotubes.

Authors:  Jared J Crochet; Juan G Duque; James H Werner; Stephen K Doorn
Journal:  Nat Nanotechnol       Date:  2012-01-10       Impact factor: 39.213

2.  Tracking clathrin coated pits with a multiple hypothesis based method.

Authors:  Liang Liang; Hongying Shen; Pietro De Camilli; James S Duncan
Journal:  Med Image Comput Comput Assist Interv       Date:  2010

3.  Molecular and Mechanical Causes of Microtubule Catastrophe and Aging.

Authors:  Pavel Zakharov; Nikita Gudimchuk; Vladimir Voevodin; Alexander Tikhonravov; Fazoil I Ataullakhanov; Ekaterina L Grishchuk
Journal:  Biophys J       Date:  2015-12-15       Impact factor: 4.033

4.  Real-time Imaging and Quantification of Fungal Biofilm Development Using a Two-Phase Recirculating Flow System.

Authors:  Andrew D McCall; Mira Edgerton
Journal:  J Vis Exp       Date:  2018-10-18       Impact factor: 1.355

5.  Fluorescence microscopy evidence for quasi-permanent attachment of antifreeze proteins to ice surfaces.

Authors:  Natalya Pertaya; Christopher B Marshall; Carlos L DiPrinzio; Larry Wilen; Erik S Thomson; J S Wettlaufer; Peter L Davies; Ido Braslavsky
Journal:  Biophys J       Date:  2007-02-26       Impact factor: 4.033

6.  Supercritical angle fluorescence correlation spectroscopy.

Authors:  Jonas Ries; Thomas Ruckstuhl; Dorinel Verdes; Petra Schwille
Journal:  Biophys J       Date:  2007-09-07       Impact factor: 4.033

7.  Total internal reflection fluorescence correlation spectroscopy: effects of lateral diffusion and surface-generated fluorescence.

Authors:  Jonas Ries; Eugene P Petrov; Petra Schwille
Journal:  Biophys J       Date:  2008-03-13       Impact factor: 4.033

Review 8.  Three-Dimensional Localization of Single Molecules for Super-Resolution Imaging and Single-Particle Tracking.

Authors:  Lexy von Diezmann; Yoav Shechtman; W E Moerner
Journal:  Chem Rev       Date:  2017-02-02       Impact factor: 60.622

9.  Quantitative study of single molecule location estimation techniques.

Authors:  Anish V Abraham; Sripad Ram; Jerry Chao; E S Ward; Raimund J Ober
Journal:  Opt Express       Date:  2009-12-21       Impact factor: 3.894

10.  A novel multiple hypothesis based particle tracking method for clathrin mediated endocytosis analysis using fluorescence microscopy.

Authors:  Pietro De Camilli; James S Duncan
Journal:  IEEE Trans Image Process       Date:  2014-04       Impact factor: 10.856

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.