Literature DB >> 17356616

Polarization effects on scatterer sizing accuracy analyzed with frequency-domain angle-resolved low-coherence interferometry.

John W Pyhtila1, Adam Wax.   

Abstract

Angle-resolved low-coherence interferometry (a/LCI) enables us to make depth-resolved measurements of scattered light that can be used to recover subsurface structural information such as the size of cell nuclei. Endoscopic frequency-domain a/LCI (fa/LCI) acquires data by using a novel fiber probe in a fraction of a second, making it a clinically practical system. However, birefringent effects in fiber-based systems can alter the polarization state of the incident light and potentially skew the collected data. We analyze the effect the polarization state of the incident light has on scattering data collected from polystyrene microsphere tissue phantoms and in vitro cell samples and examine the subsequent accuracy of the determined sizes. It is shown that the endoscopic fa/LCI system accurately determines the size of polystyrene microspheres without the need to control the polarization of the incident beam, but that epithelial cell nuclear sizes are accurately determined only when the polarization state of the incident light is well characterized.

Entities:  

Mesh:

Year:  2007        PMID: 17356616     DOI: 10.1364/ao.46.001735

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  4 in total

1.  Detection of intestinal dysplasia using angle-resolved low coherence interferometry.

Authors:  Neil Terry; Yizheng Zhu; Julie K M Thacker; John Migaly; Cynthia Guy; Christopher R Mantyh; Adam Wax
Journal:  J Biomed Opt       Date:  2011-10       Impact factor: 3.170

2.  Label-free, high-throughput measurements of dynamic changes in cell nuclei using angle-resolved low coherence interferometry.

Authors:  Kevin J Chalut; Sulin Chen; John D Finan; Michael G Giacomelli; Farshid Guilak; Kam W Leong; Adam Wax
Journal:  Biophys J       Date:  2008-03-07       Impact factor: 4.033

3.  Fiber-optic interferometric two-dimensional scattering-measurement system.

Authors:  Yizheng Zhu; Michael G Giacomelli; Adam Wax
Journal:  Opt Lett       Date:  2010-05-15       Impact factor: 3.776

Review 4.  Optical measurement of arterial mechanical properties: from atherosclerotic plaque initiation to rupture.

Authors:  Seemantini K Nadkarni
Journal:  J Biomed Opt       Date:  2013-12       Impact factor: 3.170

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.