Literature DB >> 17356086

Respiratory polygraphy with actigraphy in the diagnosis of sleep apnea-hypopnea syndrome.

Emilio García-Díaz1, Esther Quintana-Gallego2, Aránzazu Ruiz3, Carmen Carmona-Bernal3, Ángeles Sánchez-Armengol3, Georgina Botebol-Benhamou4, Francisco Capote3.   

Abstract

OBJECTIVE: To determine the utility and reliability of a respiratory polygraphy (RP) device with actigraphy (Apnoescreen II; Erich Jaeger GMBH & CoKg; Wuerzburg, Germany) in the diagnosis of sleep apnea-hypopnea syndrome (SAHS).
DESIGN: A prospective randomized study with blinded analysis. PATIENTS: Sixty-two patients with suspected SAHS. MEASUREMENTS: the following two RP studies were performed: one in the sleep laboratory (sleep laboratory RP [LRP]), simultaneously with polysomnography; and the other at home (home RP [HRP]). To study the interobserver reliability of RP, two manual analyses were carried out by two different researchers.
RESULTS: In LRP, when the respiratory disturbance index was calculated using the total sleep time estimated by actigraphy (RDI) as a denominator, the sensitivity ranged between 94.6% and 100%, and the specificity between 88% and 96.7% for the different cutoff points of the apnea-hypopnea indexes studied. When the respiratory disturbance index was calculated according to the total recording time (RDITRT), the sensitivity was slightly lower (91.6 to 96.9%) and the specificity was similar (92 to 96.7%). In HRP, the sensitivity of the RDI ranged between 83.8% and 95.8%, and the specificity between 92% and 100%, whereas, when the RDITRT was used, the sensitivity was between 83.8% and 87.5%, and the specificity was between 94.7% and 100%. With regard to interobserver reliability, the intraclass correlation coefficient for the RDI of the two analyses of the RP was 0.99 for both LPR and HPR.
CONCLUSION: HPR is an effective and reliable technique for the diagnosis of SAHS, although it is less sensitive than LRP. Wrist actigraphy improves the results of HRP only slightly.

Entities:  

Mesh:

Year:  2007        PMID: 17356086     DOI: 10.1378/chest.06-1604

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  21 in total

Review 1.  Phosphinic peptides as zinc metalloproteinase inhibitors.

Authors:  V Dive; D Georgiadis; M Matziari; A Makaritis; F Beau; P Cuniasse; A Yiotakis
Journal:  Cell Mol Life Sci       Date:  2004-08       Impact factor: 9.261

Review 2.  Obstructive sleep apnea devices for out-of-center (OOC) testing: technology evaluation.

Authors:  Nancy A Collop; Sharon L Tracy; Vishesh Kapur; Reena Mehra; David Kuhlmann; Sam A Fleishman; Joseph M Ojile
Journal:  J Clin Sleep Med       Date:  2011-10-15       Impact factor: 4.062

3.  Estimating sleep time from non-EEG-based PSG signals in the diagnosis of sleep-disordered breathing.

Authors:  M B Norman; C E Sullivan
Journal:  Sleep Breath       Date:  2017-02-03       Impact factor: 2.816

Review 4.  Wrist actigraphy.

Authors:  Jennifer L Martin; Alex D Hakim
Journal:  Chest       Date:  2011-06       Impact factor: 9.410

5.  Electro-oculography-based detection of sleep-wake in sleep apnea patients.

Authors:  Jussi Virkkala; Jussi Toppila; Paula Maasilta; Adel Bachour
Journal:  Sleep Breath       Date:  2014-10-01       Impact factor: 2.816

6.  EOG-based auto-staging: less is more.

Authors:  Christian Berthomier; Marie Brandewinder
Journal:  Sleep Breath       Date:  2015-02-06       Impact factor: 2.816

7.  Discordant sleep parameters among actigraphy, polysomnography, and perceived sleep in patients with sleep-disordered breathing in comparison with patients with chronic insomnia disorder.

Authors:  Su Jung Choi; Miri Kang; Min Je Sung; Eun Yeon Joo
Journal:  Sleep Breath       Date:  2017-06-14       Impact factor: 2.816

8.  Accuracy of portable devices in sleep apnea using oximetry-derived heart rate increases as a surrogate arousal marker.

Authors:  Philippe Lachapelle; Juan Cascon; Sushmita Pamidi; R John Kimoff
Journal:  Sleep Breath       Date:  2018-08-15       Impact factor: 2.816

9.  Portable monitoring devices for diagnosis of obstructive sleep apnea at home: review of accuracy, cost-effectiveness, guidelines, and coverage in Canada.

Authors: 
Journal:  CADTH Technol Overv       Date:  2010-12-01

Review 10.  Diagnostic accuracy of level 3 portable sleep tests versus level 1 polysomnography for sleep-disordered breathing: a systematic review and meta-analysis.

Authors:  Mohamed El Shayeb; Leigh-Ann Topfer; Tania Stafinski; Lawrence Pawluk; Devidas Menon
Journal:  CMAJ       Date:  2013-11-11       Impact factor: 8.262

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.