Augmentation of an anterior lumbar interbody fusion with an anterior plate or pedicle screw fixation: a comparative biomechanical in vitro study.

Tann A Nichols1, Brenda K Yantzer, Suzanne Alameda, Wesley M Johnson, Bernard H Guiot.   

Abstract

OBJECT: Posterior pedicle screw (PS) instrumentation is often used to augment anterior lumbar interbody fusion (ALIF) but at the cost of an increase in the morbidity rate due to the second approach and screw placement. If anterior plates were found to be biomechanically equivalent to PS fixation (PSF) after ALIF, then this second approach could be avoided without decreasing vertebral stability.
METHODS: Eight cadaveric L5-S1 spinal segments were tested under four conditions: intact, following anterior discectomy and interbody spacer placement, after placement of an anterior plate, and following PSF. The elastic zone and stiffness were calculated for axial compression, flexion/extension, lateral bending, and torsion. Neither anterior plate stabilization nor PSF showed significant intergroup differences in stiffness or the elastic zone. Both exhibited greater stiffness in flexion than the intact specimens (p < 0.001). Pedicle screw fixation was associated with a decreased elastic zone in lateral bending compared with the intact specimen (p < 0.04).
CONCLUSIONS: Anterior plate fixation is biomechanically similar to PSF following ALIF. Surgeons may wish to use anterior plates in place of PSs to avoid the need for a posterior procedure. This may lead to a decrease in operative morbidity and improved overall outcomes.

Mesh:

Year:  2007        PMID: 17355026     DOI: 10.3171/spi.2007.6.3.267

Source DB:  PubMed          Journal:  J Neurosurg Spine        ISSN: 1547-5646


  3 in total

1.  Anterior interbody arthrodesis with percutaneous posterior pedicle fixation for degenerative conditions of the lumbar spine.

Authors:  D Greg Anderson; Amirali Sayadipour; Kevin Shelby; Todd J Albert; Alexander R Vaccaro; Michael S Weinstein
Journal:  Eur Spine J       Date:  2011-04-13       Impact factor: 3.134

2.  Complication with removal of a lumbar spinal locking plate.

Authors:  Brooke Crawford; Christopher Lenarz; J Tracy Watson; Dirk Alander
Journal:  Case Rep Orthop       Date:  2015-03-09

3.  Pullout of a lumbar plate with varying screw lengths.

Authors:  Daniel Kyle Palmer; David Rios; Wyzscx Merfil Patacxil; Paul A Williams; Wayne K Cheng; Serkan İnceoğlu
Journal:  Int J Spine Surg       Date:  2012-12-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.