Literature DB >> 17350716

Three-dimensional visualization and quantification of non-aqueous phase liquid volumes in natural porous media using a medical X-ray Computed Tomography scanner.

Lucas Goldstein1, Shiv O Prasher, Subhasis Ghoshal.   

Abstract

This study demonstrates the capabilities of a typical medical X-ray Computed Tomography (CT) scanner to non-destructively quantify non-aqueous phase liquid (NAPL) volumes, saturation levels, and three-dimensional spatial distributions in packed soil columns. Columns packed with homogeneous sand, heterogeneous sand, or natural soil, were saturated with water and injected with known quantities of gasoline or tetrachloroethene and scanned. A methodology based on image subtraction was implemented for computing soil porosity and NAPL volumes in each 0.35 mm x 0.35 mm x 1 mm voxel of the columns. Elimination of sample positioning errors and instrument drift artifacts was essential for obtaining reliable estimates of above parameters. The CT data-derived total NAPL volume was in agreement with the measured NAPL volumes injected into the columns. CT data-derived NAPL volume is subject to a 2.6% error for PCE and a 15.5% error for gasoline, at average NAPL saturations as low as 5%, and is mainly due to instrument noise. Non-uniform distributions of NAPL due to preferential flow, and accumulation of NAPL above finer-grained layers could be observed from the data on 3-D distributions of NAPL volume fractions.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17350716     DOI: 10.1016/j.jconhyd.2007.01.013

Source DB:  PubMed          Journal:  J Contam Hydrol        ISSN: 0169-7722            Impact factor:   3.188


  3 in total

1.  Non-destructive Analysis of Oil-Contaminated Soil Core Samples by X-ray Computed Tomography and Low-Field Nuclear Magnetic Resonance Relaxometry: a Case Study.

Authors:  Yoshito Nakashima; Yuji Mitsuhata; Junko Nishiwaki; Yoshishige Kawabe; Shin Utsuzawa; Motoharu Jinguuji
Journal:  Water Air Soil Pollut       Date:  2010-05-22       Impact factor: 2.520

Review 2.  A review of non-invasive imaging methods and applications in contaminant hydrogeology research.

Authors:  Charles J Werth; Changyong Zhang; Mark L Brusseau; Mart Oostrom; Thomas Baumann
Journal:  J Contam Hydrol       Date:  2010-01-28       Impact factor: 3.188

Review 3.  Sorption of hydrophobic organic compounds on natural sorbents and organoclays from aqueous and non-aqueous solutions: a mini-review.

Authors:  Francis Moyo; Roman Tandlich; Brendan S Wilhelmi; Stefan Balaz
Journal:  Int J Environ Res Public Health       Date:  2014-05-09       Impact factor: 3.390

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.