Literature DB >> 17350524

Spread of injectate associated with radial or median nerve-type motor response during infraclavicular brachial-plexus block: an ultrasound evaluation.

Sébastien Bloc1, Thierry Garnier, Bernard Komly, Hugues Asfazadourian, Pascal Leclerc, Luc Mercadal, Bertrand Morel, Gilles Dhonneur.   

Abstract

BACKGROUND AND OBJECTIVES: We have compared ultrasound characteristics of spread during infraclavicular brachial-plexus blocks by use of electrically evoked radial-nerve- or median-nerve-type distal motor responses to guide the injection of 30 mL of 1.5% mepivacaine.
METHODS: Consecutive patients who required surgery distal to the upper arm were prospectively included in this study. With radial- or median-evoked distal motor response at a stimulating current intensity of less than 0.5 mA, patients were distributed into 2 equal groups. An independent investigator blinded to the evoked response described ultrasound characteristics of the spread of local anesthetic and assessed block quality 30 minutes after placement. A quality diffusion score proportional to the extent and intensity of spread around the axillary artery was used, and dynamic movements during injection were noted.
RESULTS: Thirty-two patients were included. With radial-nerve-type motor response, the success rate of infraclavicular plexus block was 100%, but 3 supplemental axillary blocks were requested with median-nerve-type motor response. Quality diffusion scores were significantly higher with radial-nerve-type as compared with median-nerve-type motor response (P = .03). Injection after radial-nerve-type motor response resulted in a typical and reproducible ultrasound feature of posterior local-anesthetic spread associated with medial and upper movement of the axillary artery. With median-nerve-type motor response, failed blocks were associated with a specific posterior displacement of the axillary artery that resulted from superficial spread.
CONCLUSION: We have demonstrated that as compared with median-nerve-type motor response, injection performed after a radial-nerve-type motor response promoted reproducible and remarkable ultrasound spread characteristics associated with complete sensory block of the 3 cords at 30 minutes.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17350524     DOI: 10.1016/j.rapm.2006.11.012

Source DB:  PubMed          Journal:  Reg Anesth Pain Med        ISSN: 1098-7339            Impact factor:   6.288


  2 in total

Review 1.  Upper extremity regional anesthesia: essentials of our current understanding, 2008.

Authors:  Joseph M Neal; J C Gerancher; James R Hebl; Brian M Ilfeld; Colin J L McCartney; Carlo D Franco; Quinn H Hogan
Journal:  Reg Anesth Pain Med       Date:  2009 Mar-Apr       Impact factor: 6.288

2.  Use of a curved needle to facilitate lateral sagittal infraclavicular block performance: a randomized clinical trial.

Authors:  Tarek F Tammam; Ghada A Kamhawy
Journal:  J Anesth       Date:  2019-08-29       Impact factor: 2.078

  2 in total