Literature DB >> 17350354

Enantioselective determination of azelnidipine in human plasma using liquid chromatography-tandem mass spectrometry.

Kiyoshi Kawabata1, Naozumi Samata, Yoko Urasaki, Ichiro Fukazawa, Naoki Uchida, Eiji Uchida, Hajime Yasuhara.   

Abstract

A sensitive and simple method was developed for determination of the enantiomers of azelnidipine, (R)-(-)-azelnidipine and (S)-(+)-azelnidipine, in human plasma using chiral liquid chromatography with positive ion atmospheric pressure chemical ionization tandem mass spectrometry. Plasma samples spiked with stable isotope-labeled azelnidipine, [(2)H(6)]-azelnidipine, as an internal standard, were processed for analysis using a solid-phase extraction in a 96-well plate format. The azelnidipine enantiomers were separated on a chiral column containing alpha(1)-acid glycoprotein as a chiral selector under isocratic mobile phase conditions. Acquisition of mass spectrometric data was performed in multiple reaction monitoring mode, monitoring the transitions from m/z 583-->167 for (R)-(-)-azelnidipine and (S)-(+)-azelnidipine, and from m/z 589-->167 for [(2)H(6)]-azelnidipine. The standard curve was linear over the studied range (0.05-20 ng/mL), with r(2)>0.997 using weighted (1/x(2)) quadratic regression, and the chromatographic run time was 5.0 min/injection. The intra- and inter-assay precision (coefficient of variation), calculated from the assay data of the quality control samples, was 1.2-8.2% and 2.4-5.8% for (R)-(-)-azelnidipine and (S)-(+)-azelnidipine, respectively. The accuracy was 101.2-117.0% for (R)-(-)-azelnidipine and 100.0-107.0% for (S)-(+)-azelnidipine. The overall recoveries for (R)-(-)-azelnidipine and (S)-(+)-azelnidipine were 71.4-79.7% and 71.7-84.2%, respectively. The lower limit of quantification for both enantiomers was 0.05 ng/mL using 1.0 mL of plasma. All the analytes showed acceptable short-term, long-term, auto-sampler and stock solution stability. Furthermore, the method described above was used to separately measure the concentrations of the azelnidipine enantiomers in plasma samples collected from healthy subjects who had received a single oral dose of 16 mg of azelnidipine.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17350354     DOI: 10.1016/j.jchromb.2007.01.050

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  4 in total

Review 1.  High performance affinity chromatography and related separation methods for the analysis of biological and pharmaceutical agents.

Authors:  Chenhua Zhang; Elliott Rodriguez; Cong Bi; Xiwei Zheng; Doddavenkatana Suresh; Kyungah Suh; Zhao Li; Fawzi Elsebaei; David S Hage
Journal:  Analyst       Date:  2018-01-15       Impact factor: 4.616

2.  Validated Stability-Indicating RP-HPLC Method for the Simultaneous Determination of Azelnidipine and Olmesartan in Their Combined Dosage Form.

Authors:  Jayvadan K Patel; Nilam K Patel
Journal:  Sci Pharm       Date:  2014-02-27

Review 3.  Clinical use of azelnidipine in the treatment of hypertension in Chinese patients.

Authors:  Bi-Lian Chen; Yin-Zhuang Zhang; Jian-Quan Luo; Wei Zhang
Journal:  Ther Clin Risk Manag       Date:  2015-02-24       Impact factor: 2.423

4.  Chromatographic Studies of Protein-Based Chiral Separations.

Authors:  Cong Bi; Xiwei Zheng; Shiden Azaria; Sandya Beeram; Zhao Li; David S Hage
Journal:  Separations       Date:  2016-09-05
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.