Literature DB >> 1734668

Rayon balls and disposable-diaper material selectively adsorb creatinine.

D M Mock1.   

Abstract

One method for the collection of urine samples from infants involves absorption of the urine on cotton balls placed in the diaper. Such samples are not timed and excretions are often expressed per mg of urinary creatinine. An assumption in this method is that the creatinine concentration is not changed by the absorption process. The concentration of creatinine in urine samples was measured before and after absorption of the urine by cotton balls, rayon balls, or diaper material over a range of wetness. For urine from both adults and infants, absorption on rayon balls and diaper material caused an important artifactual decrease in the concentration of creatinine. The effect was particularly striking in lightly wetted samples; the mean percent decrease was only 3 +/- 2% for cotton but was 9 +/- 5% for rayon (n = 10) and 13 +/- 4% for diaper material (n = 7). These data provide evidence that rayon balls and diaper material (and to a lesser extent cotton balls) selectively adsorb creatinine from human urine.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1734668     DOI: 10.1093/ajcn/55.2.326

Source DB:  PubMed          Journal:  Am J Clin Nutr        ISSN: 0002-9165            Impact factor:   7.045


  9 in total

1.  Urine collection pads: are samples reliable for urine biochemistry and microscopy?

Authors:  Peter I Macfarlane; Robert Ellis; Christopher Hughes; Christine Houghton; Robert Lord
Journal:  Pediatr Nephrol       Date:  2004-12-28       Impact factor: 3.714

2.  Impact of processing methods on urinary biomarkers analysis in neonates.

Authors:  Michelle C Starr; David J Askenazi; Stuart L Goldstein; James W MacDonald; Theo K Bammler; Zahra Afsharinejad; Patrick D Brophy; Sandra E Juul; Dennis E Mayock; Sangeeta R Hingorani
Journal:  Pediatr Nephrol       Date:  2017-08-19       Impact factor: 3.714

3.  Urinary excretion of 3-hydroxyisovaleric acid and 3-hydroxyisovaleryl carnitine increases in response to a leucine challenge in marginally biotin-deficient humans.

Authors:  Donald M Mock; Shawna L Stratton; Thomas D Horvath; Anna Bogusiewicz; Nell I Matthews; Cindy L Henrich; Amanda M Dawson; Horace J Spencer; Suzanne N Owen; Gunnar Boysen; Jeffery H Moran
Journal:  J Nutr       Date:  2011-09-14       Impact factor: 4.798

4.  Marginal biotin deficiency can be induced experimentally in humans using a cost-effective outpatient design.

Authors:  Shawna L Stratton; Cindy L Henrich; Nell I Matthews; Anna Bogusiewicz; Amanda M Dawson; Thomas D Horvath; Suzanne N Owen; Gunnar Boysen; Jeffery H Moran; Donald M Mock
Journal:  J Nutr       Date:  2011-12-07       Impact factor: 4.798

5.  Urine collected from diapers can be used for 2-D PAGE in infants and young children.

Authors:  Mary Jayne Kennedy; Angela Griffin; Ruifeng Su; Michael Merchant; Jon Klein
Journal:  Proteomics Clin Appl       Date:  2009-08       Impact factor: 3.494

6.  Urinary excretion of 3-hydroxyisovaleryl carnitine is an early and sensitive indicator of marginal biotin deficiency in humans.

Authors:  Shawna L Stratton; Thomas D Horvath; Anna Bogusiewicz; Nell I Matthews; Cindy L Henrich; Horace J Spencer; Jeffery H Moran; Donald M Mock
Journal:  J Nutr       Date:  2011-01-19       Impact factor: 4.798

7.  Quantitative measurement of urinary excretion of 3-hydroxyisovaleryl carnitine by LC-MS/MS as an indicator of biotin status in humans.

Authors:  Thomas D Horvath; Shawna L Stratton; Anna Bogusiewicz; Suzanne N Owen; Donald M Mock; Jeffery H Moran
Journal:  Anal Chem       Date:  2010-10-28       Impact factor: 6.986

8.  In vitro validation of a method for neonatal urine collection and analysis.

Authors:  Darren Ritchie; Roland Broadbent; Natalie Medlicott; David M Reith
Journal:  BMJ Paediatr Open       Date:  2019-06-26

Review 9.  Urine collection methods and dipstick testing in non-toilet-trained children.

Authors:  James Diviney; Mervyn S Jaswon
Journal:  Pediatr Nephrol       Date:  2020-09-12       Impact factor: 3.714

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.