Literature DB >> 17343721

Laser lead extraction in adult congenital heart disease.

Paul Khairy1, Jean-François Roux, Marc Dubuc, Bernard Thibault, Peter G Guerra, Laurent Macle, Lise-Andrée Mercier, Annie Dore, Denis Roy, Mario Talajic, Pierre Pagé.   

Abstract

BACKGROUND: In adults with congenital heart disease (ACHD), lead extraction procedures are expected to parallel increasing transvenous pacemaker and defibrillator implantations. We sought to assess the safety and feasibility of laser lead extraction in ACHD. METHODS AND
RESULTS: All laser lead extractions (Spectranectics, Colorado Springs, CO, USA) performed at the Montreal Heart Institute between September 2000 and August 2005 were prospectively registered. Efficacy and complications in patients with ACHD were compared to the larger cohort. Laser lead extraction was attempted on 270 leads in 175 patients. In ACHD, 23 (five atrial, 15 ventricular pacing, and three defibrillator) leads were targeted in 16 patients. Indications were: infection 44%, dysfunction 25%, upgrade 25%, and pain 6%. Patients with ACHD were younger (43.0 +/- 13.5 vs 63.7 +/- 14.7 years, P < 0.0001) and had a higher proportion of active fixation leads (74% vs 37%, P = 0.0013). Lead age in patients with and without ACHD was 9.0 +/- 5.2 vs 7.7 +/- 5.2 years (P = 0.2713). Overall, 21 of 23 leads (91%) were successfully extracted in ACHD compared with 220 of 247 leads (89%) (P = 0.7405). One major complication (6.3%) occurred in ACHD (tricuspid valve laceration) compared with five major (3.0%) and eight minor (5.0%) complications in patients without ACHD. Presence of ACHD did not modulate procedural success (OR 1.3, 95% CI [0.3, 5.8]) or complications (OR 1.0, 95% CI [0.2, 4.4]). Median procedural time was 27 minutes longer in ACHD (127 vs 100 minutes, P = 0.0595).
CONCLUSION: In selected patients with ACHD, laser lead extraction may be performed with a safety and efficacy profile comparable to patients without ACHD.

Entities:  

Mesh:

Year:  2007        PMID: 17343721     DOI: 10.1111/j.1540-8167.2007.00782.x

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  4 in total

1.  Pacemaker laser lead extraction and reimplantation of dual-chamber implantable cardioverter defibrillator via Mustard baffle in complete transposition of great arteries.

Authors:  Leo Simpson; Paul S Bhella; Jeffrey M Schussler; Paul A Grayburn; Manish Assar
Journal:  Proc (Bayl Univ Med Cent)       Date:  2010-07

2.  Pacing and Defibrillators in Complex Congenital Heart Disease.

Authors:  Henry Chubb; Mark O'Neill; Eric Rosenthal
Journal:  Arrhythm Electrophysiol Rev       Date:  2016-05

3.  Device extraction in adults with congenital heart disease.

Authors:  David Cesario; Rohit Kedia; Nirav Desai; Jamil Aboulhosn; Daniel Uslan; Noel Boyle; Osamu Fujimura; Michael Shehata; Eric Buch; Kalyanam Shivkumar
Journal:  Pacing Clin Electrophysiol       Date:  2009-03       Impact factor: 1.976

4.  Transvenous lead extraction in a patient with polysplenia and inferior vena cava defect.

Authors:  Shohei Kataoka; Morio Shoda; Satoshi Saito; Daigo Yagishita; Kyoichiro Yazaki; Satoshi Higuchi; Miwa Kanai; Koichiro Ejima; Nobuhisa Hagiwara
Journal:  J Cardiol Cases       Date:  2020-10-02
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.