Literature DB >> 1734178

Diffusion imaging of the human brain in vivo using high-speed STEAM MRI.

K D Merboldt1, W Hänicke, H Bruhn, M L Gyngell, J Frahm.   

Abstract

This paper describes a new method for diffusion imaging of the human brain in vivo that is based on a combination of diffusion-encoding gradients with high-speed STEAM MR imaging. The single-shot sequence 90 degrees-TE/2-90 degrees-TM-(alpha-TE/2-STE)n generates n = 32-64 differently phase-encoded stimulated echoes STE yielding image acquisition times of 576 ms for a 48 x 128 data matrix. Diffusion encoding is performed during the first TE/2-interval as well as during each readout period. Phantom studies reveal a quantitative agreement of calculated diffusion coefficients with literature values. EKG triggering completely eliminates motion artifacts from diffusion-weighted single-shot STEAM images of human brain in vivo. While signal attenuation of the cerebrospinal fluid (CSF) is predominantly due to flow, that observed for gray and white matter results from diffusion. Evaluated diffusion coefficients yield (1.0 +/- 0.1) x 10(-5) cm2 s-1 for gray matter, (0.5 +/- 0.1) x 10(-5) cm2 s-1 for white matter with the diffusion encoding parallel to the main orientation of the myelin sheath of the neurofibrils, and (0.3 +/- 0.1) x 10(-5) cm2 s-1 for white matter and a perpendicular orientation. All studies were performed at 2.0 T using a conventional 10 mT m-1 gradient system.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1734178     DOI: 10.1002/mrm.1910230119

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  10 in total

1.  Diffusion weighted magnetic resonance imaging of compromised tissue in stroke.

Authors:  A Connelly; W K Chong; C L Johnson; V Ganesan; D G Gadian; F J Kirkham
Journal:  Arch Dis Child       Date:  1997-07       Impact factor: 3.791

Review 2.  Foundations of advanced magnetic resonance imaging.

Authors:  Roland Bammer; Stefan Skare; Rexford Newbould; Chunlei Liu; Vincent Thijs; Stefan Ropele; David B Clayton; Gunnar Krueger; Michael E Moseley; Gary H Glover
Journal:  NeuroRx       Date:  2005-04

3.  A tractography comparison between turboprop and spin-echo echo-planar diffusion tensor imaging.

Authors:  Minzhi Gui; Huiling Peng; John D Carew; Maciej S Lesniak; Konstantinos Arfanakis
Journal:  Neuroimage       Date:  2008-06-21       Impact factor: 6.556

4.  Single-shot T1 mapping using simultaneous acquisitions of spin- and stimulated-echo-planar imaging (2D ss-SESTEPI).

Authors:  Xianfeng Shi; Seong-Eun Kim; Eun-Kee Jeong
Journal:  Magn Reson Med       Date:  2010-09       Impact factor: 4.668

5.  Diffusion-weighted MR imaging of experimental brain tumors in rats.

Authors:  T Els; M Eis; M Hoehn-Berlage; K A Hossmann
Journal:  MAGMA       Date:  1995-03       Impact factor: 2.310

Review 6.  Diffusion-weighted magnetic resonance imaging in cancer: Reported apparent diffusion coefficients, in-vitro and in-vivo reproducibility.

Authors:  Maysam M Jafar; Arman Parsai; Marc E Miquel
Journal:  World J Radiol       Date:  2016-01-28

Review 7.  Functional imaging in adult and paediatric brain tumours.

Authors:  Andrew C Peet; Theodoros N Arvanitis; Martin O Leach; Adam D Waldman
Journal:  Nat Rev Clin Oncol       Date:  2012-11-13       Impact factor: 66.675

8.  Comparison of in vivo and ex vivo diffusion tensor imaging in rhesus macaques at short and long diffusion times.

Authors:  Swati Rane; Timothy Q Duong
Journal:  Open Neuroimag J       Date:  2011-11-18

9.  QuickBundles, a Method for Tractography Simplification.

Authors:  Eleftherios Garyfallidis; Matthew Brett; Marta Morgado Correia; Guy B Williams; Ian Nimmo-Smith
Journal:  Front Neurosci       Date:  2012-12-11       Impact factor: 4.677

10.  Sensitivity of Diffusion-Weighted STEAM MRI and EPI-DWI to Infratentorial Ischemic Stroke.

Authors:  Ahmed A Khalil; Marc Hohenhaus; Claudia Kunze; Wolf Schmidt; Peter Brunecker; Kersten Villringer; Klaus-Dietmar Merboldt; Jens Frahm; Jochen B Fiebach
Journal:  PLoS One       Date:  2016-08-16       Impact factor: 3.240

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.