Literature DB >> 1733530

A comparison of transcutaneous end-tidal and arterial measurements of carbon dioxide during general anaesthesia.

C W Reid1, R J Martineau, D R Miller, K A Hull, J Baines, P J Sullivan.   

Abstract

A randomized, prospective study was performed to evaluate the accuracy of a new transcutaneous carbon dioxide (CO2) monitor (Fastrac) during general anaesthesia. Twenty-two adult patients undergoing elective surgery were subjected to three different levels of minute ventilation by varying their respiratory rates in a randomized cross-over design. Simultaneous measurements of transcutaneous CO2 (PTCCO2) and arterial CO2 (PaCO2) were obtained at three levels of minute ventilation (low, medium and high). End-tidal CO2 (PETCO2) values were also recorded from a mass spectrometer (SARA) at each time period. A total of 66 data sets with PaCO2 ranging from 28-62 mmHg were analyzed. The PTCCO2 values demonstrated a high degree of correlation with PaCO2 over the range of minute ventilation (y = 0.904x + 6.36, r = 0.92, P less than 0.001). The PETCO2 measurement also demonstrated a generally good correlation with PaCO2 (y = 0.62x + 9.21, r = 0.89, and P less than 0.01). However, the PETCO2-PaCO2 gradients (mean 7.0 +/- 3.1 mmHg) were greater than the PTCCO2-PaCO2 gradients (mean 2.3 +/- 2.4 mmHg) at all three levels of minute ventilation (P less than 0.05). These differences were greatest when PaCO2 was in the high range (48-60 mmHg). We conclude that the new Fastrac CO2 monitor is accurate for monitoring carbon dioxide levels during general anaesthesia. The new transcutaneous devices provide an effective method for non-invasive monitoring of CO2 in situations where continuous, precise control of CO2 levels is desired.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1733530     DOI: 10.1007/BF03008669

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  16 in total

1.  Respiratory dead space and arterial to end-tidal carbon dioxide tension difference in anesthetized man.

Authors:  J F NUNN; D W HILL
Journal:  J Appl Physiol       Date:  1960-05       Impact factor: 3.531

2.  Pro: Blood gases should be corrected for temperature during hypothermic cardiopulmonary bypass: pH-stat mode.

Authors:  J H Tinker; J H Campos
Journal:  J Cardiothorac Anesth       Date:  1988-10

3.  Smoking, age and the arterial-end-tidal PCO2 difference during anaesthesia and controlled ventilation.

Authors:  R Fletcher
Journal:  Acta Anaesthesiol Scand       Date:  1987-05       Impact factor: 2.105

4.  The validity and usefulness of the end-tidal pCO 2 during anaesthesia.

Authors:  S Takki; U Aromaa; A Kauste
Journal:  Ann Clin Res       Date:  1972-10

5.  Cutaneous blood gas monitoring in the adult.

Authors:  P Eberhard; W Mindt; R Schäfer
Journal:  Crit Care Med       Date:  1981-10       Impact factor: 7.598

6.  Automated respiratory gas monitoring of critically injured patients.

Authors:  T C McAslan
Journal:  Crit Care Med       Date:  1976 Sep-Oct       Impact factor: 7.598

7.  Deadspace and the single breath test for carbon dioxide during anaesthesia and artificial ventilation. Effects of tidal volume and frequency of respiration.

Authors:  R Fletcher; B Jonson
Journal:  Br J Anaesth       Date:  1984-02       Impact factor: 9.166

8.  Variation in PCO2 between arterial blood and peak expired gas during anesthesia.

Authors:  D B Raemer; D Francis; J H Philip; R A Gabel
Journal:  Anesth Analg       Date:  1983-12       Impact factor: 5.108

9.  On-line measurement of gas-exchange during cardiac surgery.

Authors:  R Fletcher; G Malmkvist; L Niklason; B Jonson
Journal:  Acta Anaesthesiol Scand       Date:  1986-05       Impact factor: 2.105

10.  Relationship between transcutaneous and arterial carbon dioxide tension in adult patients anesthetized with nitrous oxide-fentanyl and nitrous oxide-enflurane.

Authors:  T D Rafferty; O Marrero; D Nardi; E N Schachter; R Mentelos; A Hastings; D Roselli
Journal:  Anesth Analg       Date:  1981-07       Impact factor: 5.108

View more
  7 in total

1.  Recent advance in patient monitoring.

Authors:  Tomoki Nishiyama
Journal:  Korean J Anesthesiol       Date:  2010-09-20

2.  A comparison of the incidence of hypercapnea in non-obese and morbidly obese peri-operative patients using the SenTec transcutaneous pCO(2) monitor.

Authors:  Roy G Soto; Maurice Davis; Michael J Faulkner
Journal:  J Clin Monit Comput       Date:  2013-11-29       Impact factor: 2.502

3.  Increase in cerebrospinal fluid pressure in normocapnic volunteers in response to nalbuphine.

Authors:  A Benzer; R Hüssler; L Russegger; A Faserl; D Balogh
Journal:  Eur J Clin Pharmacol       Date:  1992       Impact factor: 2.953

4.  Carbon dioxide monitoring during laparoscopic-assisted bariatric surgery in severely obese patients: transcutaneous versus end-tidal techniques.

Authors:  Joanna M Dion; Chris McKee; Joseph D Tobias; Daniel Herz; Paul Sohner; Steven Teich; Marc Michalsky
Journal:  J Clin Monit Comput       Date:  2014-06-11       Impact factor: 2.502

5.  Noninvasive monitoring of PaCO(2) during one-lung ventilation and minimal access surgery in adults: End-tidal versus transcutaneous techniques.

Authors:  Paul Cox; Joseph D Tobias
Journal:  J Minim Access Surg       Date:  2007-01       Impact factor: 1.407

6.  The application of transcutaneous CO2 pressure monitoring in the anesthesia of obese patients undergoing laparoscopic bariatric surgery.

Authors:  Shijiang Liu; Jie Sun; Xing Chen; Yingying Yu; Xuan Liu; Cunming Liu
Journal:  PLoS One       Date:  2014-04-03       Impact factor: 3.240

7.  Strategy to Reduce Hypercapnia in Robot-Assisted Radical Prostatectomy Using Transcutaneous Carbon Dioxide Monitoring: A Prospective Observational Study.

Authors:  Hyun Jung Lee; Ji Seon Chae; Sang-Mee An; Hye-Won Oh; Youn Jin Kim; Jae Hee Woo
Journal:  Ther Clin Risk Manag       Date:  2022-03-17       Impact factor: 2.423

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.