Literature DB >> 17334071

[Optimized thread pitch design and stress analysis of the cylinder screwed dental implant].

Liang Kong1, Bao-Lin Liu, Kai-Jin Hu, De-Hua Li, Ying-Liang Song, Pan Ma, Jin Yang.   

Abstract

OBJECTIVE: To determine the optimal thread pitch for an experimental cylinder implant in Ansys Work-bench Design Xplorer environment.
METHODS: Finite element models of segment jaw bone with a V-shaped thread implant were created. The thread pitch (P) was set from 0.5 mm to 1.6 mm. The maximum Equivalent stresses (EQV stresses) in jaw bone and in implant were evaluated.
RESULTS: Under axial load, the amplification of maximum EQV stresses in cortical bone, cancellous bone and implant were 7.1%, 123.4% and 28.7% respectively. Under bucco-lingual load, the amplification of maximum EQV stresses in cortical bone, cancellous bone and implant were 2.8%, 28.8% and 14.9% respectively. When P exceeded 0.8 mm, the response curve curvature of maximum EQV stresses in jaw bone and in implant to P was ranged from -1 to 1.
CONCLUSION: Stresses in cancellous bone are more sensitive to thread pitch than in cortical bone. Stresses in jaw bone under axial load are easier affected by thread pitch than under bucco-lingual load. Thread pitch plays a greater role in protecting dental implant under axial load than under bucco-lingual load. Thread pitch exceed 0.8 mm should be the optimal design in a cylinder implant, but oversized pitch should be avoided too.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17334071

Source DB:  PubMed          Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi        ISSN: 1000-1182


  5 in total

1.  The influence of thread geometry on implant osseointegration under immediate loading: a literature review.

Authors:  Hyo-Sook Ryu; Cheol Namgung; Jong-Ho Lee; Young-Jun Lim
Journal:  J Adv Prosthodont       Date:  2014-12-17       Impact factor: 1.904

2.  Effect of thread depth and thread pitch on the primary stability of miniscrews receiving a torque load : A finite element analysis.

Authors:  Yushan Ye; Weimin Yi; Song Fan; Luodan Zhao; Yansong Yu; Yingjuan Lu; Qinghe Yao; Wei Wang; Shaohai Chang
Journal:  J Orofac Orthop       Date:  2021-09-28       Impact factor: 1.938

3.  Effect of microthreads on removal torque and bone-to-implant contact: an experimental study in miniature pigs.

Authors:  Yee-Seo Kwon; Hee Namgoong; Jung-Hoon Kim; In Hee Cho; Myung Duk Kim; Tae Gwan Eom; Ki-Tae Koo
Journal:  J Periodontal Implant Sci       Date:  2013-02-28       Impact factor: 2.614

4.  Effect of thread depth and implant shape on stress distribution in anterior and posterior regions of mandible bone: A finite element analysis.

Authors:  Falah A Hussein; Kareem N Salloomi; Besaran Y Abdulrahman; Abdulsalam R Al-Zahawi; Laith A Sabri
Journal:  Dent Res J (Isfahan)       Date:  2019 May-Jun

5.  Failure Modes and Survival of Anterior Crowns Supported by Narrow Implant Systems.

Authors:  Edmara T P Bergamo; Everardo N S de Araújo-Júnior; Adolfo C O Lopes; Paulo G Coelho; Abbas Zahoui; Ernesto B Benalcázar Jalkh; Estevam A Bonfante
Journal:  Biomed Res Int       Date:  2020-09-07       Impact factor: 3.411

  5 in total