Literature DB >> 17331635

Resin-dentin bond strength as related to different surface preparation methods.

Vanthana Sattabanasuk1, Viracha Vachiramon, Fang Qian, Steven R Armstrong.   

Abstract

OBJECTIVE: To determine the microtensile bond strength and micromorphological structures on bonding of two adhesives (OptiBond FL and Clearfil SE Bond) to dentin surfaces ground with different preparation methods.
METHODS: Extracted human molars were ground flat to expose mid-coronal occlusal dentin surface with one of six preparation methods--P120 grit SiC paper, P400 grit SiC paper, P1200 grit SiC paper, medium grit diamond bur, fine grit diamond bur, and carbide bur. Each of the adhesives was used to bond resin-based composite to the dentin surface. Dumbbell-shaped specimens were fabricated and microtensile bond strengths were determined. The subsequent debond pathway and micromorphological structures of representative dentin surfaces were examined under scanning electron microscopy. ANOVA and survival analyses were performed both assuming independence from and accommodating for within-tooth correlation between specimens.
RESULTS: By ignoring the correlations between specimens, statistical analyses revealed no surface preparation effect on microtensile bond strength for each adhesive system. However, effects of surface preparation method on dentin adhesion of both adhesives were detected when accommodating for any within-tooth specimen correlations. Overall, carbide bur group showed the lowest bond strength for both OptiBond FL and Clearfil SE Bond. Dentin surfaces ground with diamond burs tended to present more compact smear layer than those ground with SiC papers and, subsequently, produced an effect on resin-dentin bond strengths.
CONCLUSIONS: The dentin surface preparation method affects smear layer characteristics and dentin surface topography and, therefore affects resin-dentin bond strength. Smear layer denseness, more so than thickness, may compromise bonding efficacy of adhesives, especially of the self-etch systems.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17331635     DOI: 10.1016/j.jdent.2007.01.002

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  12 in total

1.  Comparison of the Er,Cr:YSGG laser with a chemical vapour deposition bur and conventional techniques for cavity preparation: a microleakage study.

Authors:  A Rüya Yazici; Zeren Yıldırım; Sibel A Antonson; Evren Kilinc; Daniele Koch; Donald E Antonson; Berrin Dayangaç; Gül Ozgünaltay
Journal:  Lasers Med Sci       Date:  2010-09-15       Impact factor: 3.161

2.  Long-term bonding to eroded dentin requires superficial bur preparation.

Authors:  Brigitte Zimmerli; Jan De Munck; Adrian Lussi; Paul Lambrechts; Bart Van Meerbeek
Journal:  Clin Oral Investig       Date:  2011-12-08       Impact factor: 3.573

3.  An in vitro comparison of adhesive techniques and rotary instrumentation on shear bond strength of nanocomposite with simulated pulpal pressure.

Authors:  Jayshree Hegde; Y Sravanthi
Journal:  J Conserv Dent       Date:  2011-07

4.  The effect of cutting efficacy of diamond burs on microleakage of class v resin composite restorations using total etch and self etch adhesive systems.

Authors:  M R Malekipour; F Shirani; S Tahmourespour
Journal:  J Dent (Tehran)       Date:  2010-09-30

5.  Efficacy of various cleaning solutions on saliva-contaminated zirconia for improved resin bonding.

Authors:  Da-Hye Kim; Jun-Sik Son; Seong-Hwa Jeong; Young-Kyung Kim; Kyo-Han Kim; Tae-Yub Kwon
Journal:  J Adv Prosthodont       Date:  2015-04-23       Impact factor: 1.904

Review 6.  Validity of bond strength tests: A critical review-Part II.

Authors:  Kantheti Sirisha; Tankonda Rambabu; Yalavarthi Ravishankar; Pabbati Ravikumar
Journal:  J Conserv Dent       Date:  2014-09

7.  Bond strength of resin modified glass ionomer cement to primary dentin after cutting with different bur types and dentin conditioning.

Authors:  Rebeca Di Nicoló; Luciana Keiko Shintome; Silvio Issáo Myaki; Marcos Paulo Nagayassu
Journal:  J Appl Oral Sci       Date:  2007-10       Impact factor: 2.698

8.  Analysis of resin-dentin interface morphology and bond strength evaluation of core materials for one stage post-endodontic restorations.

Authors:  Kerstin Bitter; Christin Gläser; Konrad Neumann; Uwe Blunck; Roland Frankenberger
Journal:  PLoS One       Date:  2014-02-28       Impact factor: 3.240

9.  The effect of a desensitizer and CO2 laser irradiation on bond performance between eroded dentin and resin composite.

Authors:  Meng Ding; Sang-Wan Shin; Min-Soo Kim; Jae-Jun Ryu; Jeong-Yol Lee
Journal:  J Adv Prosthodont       Date:  2014-06-24       Impact factor: 1.904

10.  Variable Smear Layer and Adhesive Application: The Pursuit of Clinical Relevance in Bond Strength Testing.

Authors:  Abu Faem Mohammad Almas Chowdhury; Rafiqul Islam; Arefin Alam; Mariko Matsumoto; Monica Yamauti; Ricardo Marins Carvalho; Hidehiko Sano
Journal:  Int J Mol Sci       Date:  2019-10-29       Impact factor: 5.923

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.