Literature DB >> 17328211

Efficacy of removal of CCL viruses under enhanced coagulation conditions.

Morteza Abbaszadegan1, Brooke K Mayer, Hodon Ryu, Nena Nwachuku.   

Abstract

The focus of coagulation as a water treatment process is shifting to accommodate recent regulatory additions that strive to balance the risks between microbial and chemical contamination of drinking water. In this work, enhanced coagulation using increased ferric chloride dose and/or pH adjustment was evaluated for removal efficacy of viruses on the United States Environmental Protection Agency (USEPA) Contaminant Candidate List (CCL), their surrogates, and dissolved organic carbon (DOC). Jar tests demonstrated that optimal DOC removal was achieved using 40 mg/L FeCl3 at a pH between 5 and 6. Under these conditions, bench-scale testing resulted in a maximum removal of 2.58 log units of adenovirus type 4, 2.50 log units of feline calicivirus, 2.32 log units of MS2, 1.75 log units of PRD1, 1.52 log units of phi-X174, 2.49 log units of fr, and 56% of DOC. The trend in virus removals (MS2 and fr > PRD1 and phi-X174) was consistent between bench- and pilot-scale testing; however, pilot-plant removals exceeded bench-scale removals. Feline calicivirus was more efficiently removed than the bacteriophages, thereby suggesting potential for the bacteriophages as suitable surrogates, with MS2 and fr being more representative and PRD1 and phi-X174 (which were removed to a lesser extent) more conservative. The bacteriophages do not appear to be appropriate surrogates for adenovirus.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17328211     DOI: 10.1021/es061517z

Source DB:  PubMed          Journal:  Environ Sci Technol        ISSN: 0013-936X            Impact factor:   9.028


  5 in total

1.  Evaluating efficacy of field-generated electrochemical oxidants on disinfection of fomites using bacteriophage MS2 and mouse norovirus MNV-1 as pathogenic virus surrogates.

Authors:  Timothy R Julian; John M Trumble; Kellogg J Schwab
Journal:  Food Environ Virol       Date:  2014-02-23       Impact factor: 2.778

2.  Applicability of integrated cell culture reverse transcriptase quantitative PCR (ICC-RTqPCR) for the simultaneous detection of the four human enteric enterovirus species in disinfection studies.

Authors:  Hodon Ryu; Karen A Schrantz; Nichole E Brinkman; Laura A Boczek
Journal:  J Virol Methods       Date:  2018-05-17       Impact factor: 2.014

3.  Elution Is a Critical Step for Recovering Human Adenovirus 40 from Tap Water and Surface Water by Cross-Flow Ultrafiltration.

Authors:  Hang Shi; Irene Xagoraraki; Kristin N Parent; Merlin L Bruening; Volodymyr V Tarabara
Journal:  Appl Environ Microbiol       Date:  2016-07-29       Impact factor: 4.792

4.  The occurrence and control of waterborne viruses in drinking water treatment: A review.

Authors:  Li Chen; Yang Deng; Shengkun Dong; Hong Wang; Pan Li; Huaiyu Zhang; Wenhai Chu
Journal:  Chemosphere       Date:  2021-04-30       Impact factor: 7.086

5.  The Impact of Capsid Proteins on Virus Removal and Inactivation During Water Treatment Processes.

Authors:  Brooke K Mayer; Yu Yang; Daniel W Gerrity; Morteza Abbaszadegan
Journal:  Microbiol Insights       Date:  2015-11-08
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.