Literature DB >> 17327661

X-ray scalpel - a new device for targeted x-ray brachytherapy and stereotactic radiosurgery.

George Gutman1, Emil Strumban, Evgeny Sozontov, Kenneth Jenrow.   

Abstract

The basic design and performance of a novel x-ray scalpel device for interstitial radiosurgery are reported. The x-ray scalpel is comprised of a capillary optics collimator conjugated with a high brilliance microfocus x-ray tube and a thin hollow needle (tip) attached to the collimator. The device is capable of producing a high dose rate (about 140 Gy min(-1) in water-like absorber at the exit window), 0.7 mm diameter, quasi-parallel beam that can be delivered to a targeted site by a minimally invasive procedure. Contrary to insertable x-ray tubes or radionuclides used in brachytherapy and complying with the 1/r(2) radiation attenuation law, the dose rate for a quasi-parallel beam decreases with distance as mu exp(-mu r), where mu is the energy-dependent linear attenuation coefficient in the exposed medium. Moreover, the shape, energy and the dose attenuation curve of the x-ray beam can be adjusted. Two versions of the x-ray scalpel device (5.4 keV and 20.2 keV) are described. We present results from our first test of the x-ray scalpel as a controllable source of focal radiation for producing radiation necrosis in rat brain tissue. Irradiation was transdurally delivered to the rat cerebral cortex for 10 min at a dose rate of 20 Gy min(-1).

Entities:  

Mesh:

Year:  2007        PMID: 17327661     DOI: 10.1088/0031-9155/52/6/015

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Radiation treatment inhibits monocyte entry into the optic nerve head and prevents neuronal damage in a mouse model of glaucoma.

Authors:  Gareth R Howell; Ileana Soto; Xianjun Zhu; Margaret Ryan; Danilo G Macalinao; Gregory L Sousa; Lura B Caddle; Katharine H MacNicoll; Jessica M Barbay; Vittorio Porciatti; Michael G Anderson; Richard S Smith; Abbot F Clark; Richard T Libby; Simon W M John
Journal:  J Clin Invest       Date:  2012-03-19       Impact factor: 14.808

2.  A vacuum-sealed miniature X-ray tube based on carbon nanotube field emitters.

Authors:  Sung Hwan Heo; Hyun Jin Kim; Jun Mok Ha; Sung Oh Cho
Journal:  Nanoscale Res Lett       Date:  2012-05-17       Impact factor: 4.703

Review 3.  Theory of Carbon Nanotube (CNT)-Based Electron Field Emitters.

Authors:  Grigory S Bocharov; Alexander V Eletskii
Journal:  Nanomaterials (Basel)       Date:  2013-07-17       Impact factor: 5.076

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.